Page 99 - Surge-Protection-E_0.pdf
P. 99
Surge Arresters – Type 2
DEHNguard PCB NPE (FM) 952 650 952 750 DG PCB NPE
DG PCB NPE FM
Single-pole base for DEHNguard modules to be mounted on the PCBs of devices, with remote signalling contact for the monitoring system
(floating changeover contact). 952 650 952 750 4013364149823 04 01 02 12 18 g 18 g
5,90 €
4013364149861 04 01 02 12
8,00 €
Type DG PCB ... NPE NPE FM
Part No. 952 650 952 750
Associated protection module DG MOD NPE (Part No. 952 050) DG MOD NPE (Part No. 952 050)
Max. continuous operating voltage (a.c.) (module) 255 V 255 V
For mounting on directly soldered into PCB directly soldered into PCB
Degree of protection IP 20 (protection module plugged in) IP 20 (protection module plugged in)
Type of remote signalling contact — changeover contact
DEHNguard PCB PV I ... FM 952 941 952 948 952 949 DG PCB PV I 500 FM
DG PCB PV I 600 FM
DG PCB PV I 750 FM
Single-pole base with increased clearance and creepage distance between the power contacts and the remote signalling contact. For instal-
lation on the PCBs of devices to accommodate DEHNguard modules, with remote signalling contact for the monitoring system (floating 952 941 952 948 4013364228177 04 01 02 12 18 g 18 g
8,00 €
4013364323919 04 01 02 12
952 949 8,00 € 4013364323926 04 01 02 12 18 g
8,00 €
changeover contact).
Type DG PCB ... PV I 500 FM PV I 600 FM PV I 750 FM
Part No. 952 941 952 948 952 949
DG MOD PV 500 DG MOD H PV 600 DG MOD H PV 750
Associated protection module
(Part No. 952 041) (Part No. 952 048) (Part No. 952 049)
Max. continuous operating voltage (d.c.) (module) 500 V 600 V 750 V
For mounting on directly soldered into PCB directly soldered into PCB directly soldered into PCB
IP 20 (protection module IP 20 (protection module IP 20 (protection module
Degree of protection
plugged in) plugged in) plugged in)
Type of remote signalling contact changeover contact changeover contact changeover contact
DEHNguard PCB PVSCI I ...FM 952 951 DG PCB PVSCI I 500FM
Single-pole base with increased clearance and creepage distance between the power contacts and the remote signalling contact. For instal-
lation on the PCBs of devices to accommodate DEHNguard modules, with remote signalling contact for the monitoring system (floating 952 951 4013364228184 04 01 02 12 18 g
8,00 €
changeover contact).
Type DG PCB ... PVSCI I 500FM
Part No. 952 951
Associated protection module DG MOD PV SCI 500 (Part No. 952 051)
Max. continuous operating voltage (d.c.) (module) 500 V
For mounting on directly soldered into PCB
Degree of protection IP 20 (protection module plugged in)
Type of remote signalling contact changeover contact
DEHNguard PCB I ... FM 952 910 DG PCB I 275 FM
Single-pole base with increased clearance and creepage distance between the power contacts and the remote signalling contact. For instal-
lation on the PCB's of devices to accommodate DEHNguard modules, with remote signalling contact for the monitoring system (floating 952 910 4013364266865 04 01 02 12 18 g
8,00 €
changeover contact).
Type DG PCB ... I 275 FM
Part No. 952 910 Surge Arresters – Type 2
Associated protection module DG MOD 275 (Part No. 952 010)
Max. continuous operating voltage (a.c.) (module) 275 V
For mounting on directly soldered into PCB
Degree of protection IP 20 (protection module plugged in)
Type of remote signalling contact changeover contact
Valid as of August 1, 2020 You will find detailed product information on our website 95