Page 82 - V16 Catalogue Final
P. 82

A
                                  C
                                   CESSORIES
                   TIBILITY
                             OF
          C
          COMPATIBILITY OF ACCESSORIES
                                 A
            OMP
                                   POSITION OF INTERNAL ACCESSORIES FOR THE TMAX XT7
                    All internal accessories for the XT7 can be mounted at the same time without any restriction concerning their compatibility. To
                    guarantee proper operation of all accessories, please refer to the relevant tables (see previous pages).




                                     AUE                                              4Q

                                     SY
                                                                                      S52
                                     PLC
                                     KLC

                                     S51



                                                   READING INFORMATION

                 Glossary       Discription                      Glossary        Discription
                 AUE            : Early auxiliary contacts        Q             : Contact signaling open/closed
                 SY             : Contact signaling tripping      S52           : Contact signaling YO/YU tripping
                 PLC            : Padlock for Circuit Breaker     YO            : Shunt opening release
                 KLC            : Keylock for Circuit Breaker     YU            : Undervoltage release
                 S51            : Contact signaling tripping due to trip unit




                                 POSITION OF INTERNAL ACCESSORIES FOR THE TMAX XT7 M
                    All internal accessories for the XT7 M can be mounted at the same time without any restriction concerning their compatibility. To
                    guarantee proper operation of all accessories, please refer to the relevant tables (see previous pages).





                                                                                    Ekip RTC

                                                                                      RTC
                                                                                       4Q
                                                                                       YC
                                                                                  Ekip Com Act.
                                    S51
                                                                                      KLC


                                    YR


                                                   READING INFORMATION
                 Glossary       Discription                      Glossary        Discription
                 S33M/2         : Contact signaling loaded springs  Q           : Contact signaling open/closed
                 MOC            : Mechanical operation counter    YC            : Closing release
                 M              : Motor operator                  Ekip COM act.  : Ekip COM actuator
                 S51            : Contact signaling tripping due to trip unit  KLC  : Keylock for Circuit Breaker
                 YR             : Remote resetting                YO            : Shunt opening release
                 Ekip RTC       : Ekip Circuit Breaker Ready to Close  YU       : Undervoltage release
                                 Signaling Contact
                 RTC            : Ready to close signaling contact


     74   V16-PD-MCCB-R04                               www.ipd.com.au                             Phone: 1300 556 601