Page 31 - MCCB-XT5
P. 31

ABB | SACE Tmax XT

                     Summary page Press on the sides of the display (1) from the Home page to access further summary pages for certain
                                    measurements:
                                     •  Main measurements page: maximum phase current, maximum line-to-line voltage, power factor,
                                       total active/reactive/apparent powers
                                     •  Ekip Synchrocheck main measurements page (when module is present): Int and Ext frequencies
                                       and voltages, phase difference, synchronism status (page 34)
















                                    Figure 16

                                           NOTE: both pages can be set as the main page by pressing HOME, holding it for five
                                           seconds and confirming the message on the display



             Measuring instruments














                                    Figure 17

                                    Depending on the Trip unit model, certain measurements acquired in real time are shown on these pages
                                    by means of a pointer; each page displays a specific measurement:
                                     Page       Measurement type page               Unit of measurement/indicator
                                     1          Maximum phase current               A
                                     2          Maximum line-to-line voltage        V
                                     3          Total active power                  kW
                                     4          Total reactive power                kVAR
                                     5          Total apparent power                kVA


                                    The scale of values ranges from 0 to 125 % and refers to the rated values set (for powers: rated current x
                                    rated voltage x √3).
                                    Press on the sides of the display to browse the pages; quit the Measurement tools section with the HOME
                                    key.
                                    Page orientation (horizontal by default) can be changed in the Settings menu (page 120).
                                           NOTE: each page can be set as the main page by pressing HOME, holding it for five seconds
                                           and confirming the message on the display
















       29 | © 2022 ABB |  1SDH002039A1002 - ECN000212994                    Ekip Touch - Interface and menus | 3 - Graphic pages
   26   27   28   29   30   31   32   33   34   35   36