HVI power Conductor
2 Connection Elements for HVI power Conductor / HVI power long Conductors
Connection kit for HVI power long Conductor Ø27 mm for installation inside the tube
Connection elements for sealing the HVI power long Conductor at both ends, for implementing the sealing end of the conductor in the
819 142 HVI P LO ASS 27
819 142 4013364152458 01 07 01 03 410 g 1
pc(s) 89,10 € supporting tube (head piece) and connection element for connection with other parts of the external lightning protection system or earth-ter-
mination system (including two heat-shrinkable sleeves).
Part No. 819 142
Material StSt
Connection bolt Ø10 mm, L 50 mm
Outside diameter Ø 30 mm
Screw threaded bolt M6 x 8 mm
PU 1 pc(s)
Connection kit for HVI power long Conductor Ø27 mm for installation outside the tube
819 149 HVI P LO ASS RAV 27
Connection kit for HVI power Conductor for installation on HVI power supporting tubes GRP / Al consisting of connection elements, threaded
819 149 4013364272057 01 07 01 03 800 g 1
pc(s) 258,53 € pins, connection part, heat-shrinkable sleeves, cable ties and fixing ring with a slotted conductor holder (Ø27 mm).
Part No. 819 149
Material StSt
Connection bolt Ø10 mm, L 50 mm
Outside diameter Ø 30 mm
Screw threaded bolt M6 x 8 mm
PU 1 pc(s)
HVI power Conductor 410 239 410 239 pc(s) 23,84 € 4013364152465 01 07 01 01 80 g 1 EB connection element for HVI power Conductor / HVI power long Conductor
PAE 27 AB11 V2A
For discharging the electric field of the HVI power Conductor (pre-assembled / on a reel) in the sealing end range.
Special slotted design to electrically contact the semi-conductive sheath.
Part No.
Material 410 239
StSt
Clamping range Ø 27 mm
Connection hole Ø 11 mm
Screw i M10 x 20 mm
PU 1 pc(s)
3 Supporting Tubes for HVI power Conductor / HVI power long Conductors
With air-termination tip
Supporting tube with internal sealing end and EB spring element. Air-termination tip, StSt, Ø10 mm, length 1000 mm.
105 563 SR D50 3500 FSP1000 IA HVIP GFK AL
105 565 SR D50 5000 FSP1000 IA HVIP GFK AL
105 320 SR D50 3500 FSP1000 IP HVIP GFK V2A
105 322 SR D50 5000 FSP1000 IP HVIP GFK V2A
Part No. 105 563 105 565 105 320 105 322
105 563 4013364271937 01 07 01 03 5.54 kg 1
pc(s) 479,98 €
105 565 4013364271944 01 07 01 03 7.92 kg 1
pc(s) 551,05 €
105 320 4013364152373 01 07 01 03 10.60 kg 1
pc(s) 589,16 €
105 322 4013364152380 01 07 01 03 15.80 kg 1 Material of supporting tube GRP / Al GRP / Al GRP / StSt GRP / StSt
pc(s) 829,15 €
Length of supporting tube 3500 mm 5000 mm 3500 mm 5000 mm
Outside diameter Ø 50 mm 50 mm 50 mm 50 mm
Transport length 3500 mm 5000 mm 3500 mm 5000 mm
Length of insulating clearance 1800 mm 1800 mm 1800 mm 1800 mm
Suitable for installation outside the tube yes yes no no
Eurocode
Max. free length with air-termination tip
(wall mounting) 4000 mm 4000 mm 4000 mm 4000 mm
Max. gust wind speed
(wall mounting, 1x HVI power inside) 203 km/h 203 km/h 235 km/h 235 km/h
Max. gust wind speed (wall mounting, 181 km/h 181 km/h — —
1x HVI power inside + 1x HVI power outside)
PU 1 pc(s) 1 pc(s) 1 pc(s) 1 pc(s)
105 573 SR D50 3500 FS2500 IA HVIP GFK AL
105 575 SR D50 5000 FS2500 IA HVIP GFK AL
105 321 SR D50 3500 FS22 10 2500 IP HVIP GFK V2A With air-termination rod
105 323 SR D50 5000 FS22 10 2500 IP HVIP GFK V2A
Supporting tube with internal sealing end and EB spring element. Air-termination rod, StSt, Ø22 / 16 / 10 mm, length 2500 mm.
105 573 4013364271975 01 07 01 03 6.40 kg 1
pc(s) 519,12 €
105 575 4013364272026 01 07 01 03 8.74 kg 1
pc(s) 623,15 €
105 321 4013364152397 01 07 01 03 12.20 kg 1
pc(s) 799,28 €
105 323 4013364152403 01 07 01 03 16.20 kg 1 Part No. 105 573 105 575 105 321 105 323
pc(s) 1.037,21 €
Material of supporting tube GRP / Al GRP / Al GRP / StSt GRP / StSt
Length of supporting tube 3500 mm 5000 mm 3500 mm 5000 mm
Outside diameter Ø 50 mm 50 mm 50 mm 50 mm
Transport length 3500 mm 5000 mm 3500 mm 5000 mm
Length of insulating clearance 1800 mm 1800 mm 1800 mm 1800 mm
Suitable for installation outside the tube yes yes no no
Eurocode
Max. free length with air-termination rod 5500 mm 5500 mm 5500 mm 5500 mm
(wall mounting)
Max. gust wind speed 173 km/h 173 km/h 169 km/h 169 km/h
(wall mounting, 1x HVI power inside)
Max. gust wind speed (wall mounting,
1x HVI power inside + 1x HVI power outside) 155 km/h 155 km/h — —
PU 1 pc(s) 1 pc(s) 1 pc(s) 1 pc(s)
198 Detailed product information can be found on our website Valid as of March 1, 2020