5. Provide Protection against adjacent Live Parts – Insulating Protective Shutters

           Type A1                                                                                          763 211   ISP 36 PVC A1...
           With finger holes, guide and limit mark for inserting and removing insulating protective shut-
           ters into / from guide rails by hand.                                                            763 211  kg      4013364081567  05 00 05 01      8.00
                                                                                                              0,00 €

           The guide mark is a dotted line with a minimum distance of 525 mm from the rear shutter
           edge. The  section  beyond  this  mark  must  not  be  contacted  when  inserting  the  insulating
           protective shutter.
           The limit mark is a continuous line and separates the handle from the protective section. The
           section  beyond  this  mark  must  not  be  contacted  when  inserting  the  insulating  protective
           shutter and must be at least 525 mm away from live parts when the shutter has been inserted.

           Type ISP 36 PVC ...         A1...
           Part No.                    763 211
           Rated voltage  (Ur)         Up to 36 kV
           Material                    Rigid PVC




           Type A2                                                                                          763 221   ISP 36 PVC A2...
           With 90° angled handle and hand grips for inserting or removing insulating protective shutters
           into / from guide rails by hand. Other angled handles (70° to 270°) are available on request.    763 221  kg      4013364081574  05 00 05 01      8.00

                                                                                                              0,00 €
           The height of the handle has to be selected in such a way that live parts of the installation
           above the shutter are completely covered.
           Type ISP 36 PVC ...         A2...
           Part No.                    763 221
           Rated voltage  (Ur)         Up to 36 kV
           Material                    Rigid PVC




           Type A3
           With retaining device with bayonet pin for inserting and removing insulating protective shut-
           ters into / from guide rails using an operating stick.
           This shutter type is also available with a longitudinal slot and a retaining device (rotable shut-
                                                                                                            763 231   ISP 36 PVC A3...
           ter). In this case, the shutter is operated using an operating stick with switching stick head.
           Two persons are required to insert / remove shutter sizes exceeding 1 m . For this purpose, two
                                                      2
           retaining devices for attaching operating sticks are required.                                   763 231  kg      4013364081581  05 00 05 01      8.00
                                                                                                              0,00 €

           Moreover, insulating protective shutters are also available with rolls.
           Type ISP 36 PVC ...         A3...
           Part No.                    763 231
           Rated voltage  (Ur)         Up to 36 kV
           Material                    Rigid PVC




           Type A4
           With finger holes (without additional marks) for use in factory assembled switchgear panels.     763 241   ISP 36 PVC A4...
           Instead of finger holes, the shutters are also available with a grip (minimum height: 35 mm).
           The shutter is inserted through a slot into the closed installation.                             763 241  kg      4013364081598  05 00 05 01      8.00

                                                                                                              0,00 €
           The protective device of the installation must ensure full protection when inserting and remov-
           ing the shutter. In type-tested switchgear installations in accordance with DIN VDE 0670-6 and
           7 or EN/IEC 62271-200 (DIN VDE 0671-200), insulating protective shutters may only be used
           in consultation with the manufacturer of the switchgear installation.
           Type ISP 36 PVC ...         A4...
           Part No.                    763 241
           Rated voltage  (Ur)         Up to 36 kV
           Material                    Rigid PVC



           Guide rails and other accessories are listed in our template (DEHN Form No. 2090/E).