Page 12 - ds103e
P. 12

Safely discharging lightning current


            Earthing and equipotential bonding at the foundation base








                                                             C
                                                                            A










                                                                                              B










             Application / Type                                                                   Part No.
             Foundation earthing
              A                Connecting clamps                                                  308 031
                               Clamps for connecting round and flat conductors in concrete foundations and reinforcements
                               with round and flat conductors with tested short circuit current carrying capacity (50 Hz).
                               Round wire 10 mm St/tZn                                            800 010
                               Round wire tested to IEC 62561-2 for use in lightning protection and earth-termination
                               systems  1) .
                               Strip 30 x 3.5 St/tZn                                              810 335
                               Strip tested to IEC 62561-2 for use in lightning protection and earth-termination systems  1) .

                               Fixed earthing terminal type M V4A                                 478 011
                               Corrosion-resistant connection of the ring earthing with the foundation earthing at the
                               base of the tower.
             Ring earth electrode
              B                Connection clamp with threaded bolt StSt (V4A)                     478 149
                               For connection of round and flat V4A conductors to fixed earthing terminals.
                               Cross unit StSt V4A                                                319 209
                               Corrosion-resistant connection of the individual ring conductors in V4A.
                               Stainless steel strip V4A                                          860 335
                               Corrosion-resistant ring conductor in V4A.
             Equipotential bonding
              C                Equipotential bonding in the tower base/equipotential busbar StSt   472 209
                               Suitable for equipotential bonding and protective/functional equipotential bonding.

















            1)  IEC 62561-2   Lightning protection system components (LPSC) – Part 2: Requirements for conductors and earth electrodes
    12
   7   8   9   10   11   12   13   14   15   16   17