Application / Type                                                                   Part No.
                External lightning protection
                              HVI power Conductor (in supporting tube with air-termination rod)      819 430
                                 ®
                              Class of LPS 1 – 200 kA (10/350 μs) – High-voltage-resistant, insulated down conductor for
                              maintaining the separation distance.

                              HVI power long Conductor (cut to length)                               819 163
                                 ®
                              Individual lengths, on request we can assemble your conductors with the appropriate
                              connection elements.
                              UNI disconnection clamp 200 kA                                         459 200
                              200 kA lightning current carrying capability according to IEC 62561-1  2) , stainless steel V2A.

                              KS connector 200 kA                                                    301 209
                              200 kA lightning current carrying capability according to IEC 62561-1  2) , stainless steel V2A.

                              MV clamp 200 kA                                                        392 209
                              200 kA lightning current carrying capability according to IEC 62561-1  2) , stainless steel V2A.
                              Lightning current carrying connection of the air-termination system and down conductor.
                              Tubular air-termination rod                                            103 419
                              Safe interception of the flash charge in permanently corrosion-resistant, stainless steel design.

                              Air-termination rod StSt                                               101 009
                              Safe interception of the flash charge in permanently corrosion-resistant, stainless steel design.

               Earthing and equipotential bonding              External lightning protection

               Safe operation of electrical equipment and systems and a   Safe interception and discharge of direct lightning strikes is
               well-functioning lightning protection system require an   paramount for the availability of a wind turbine. DEHN en-
               earth-termination system designed according to IEC   sures that this is the case by testing components like the
                                                                  ®
                       1)
               61400-24  . Connection elements which are capable of   HVI power Conductor with a lightning current of 200 kA
               carrying short-circuit current ensure the safe contact of the   (10/350 μs) as stipulated in IEC 62561. The stainless steel
               earth-termination system with metal parts of the founda-  design of the air-termination rods and connection elements
               tions and the main earthing busbar. A high level of prod-  fulfils stringent corrosion resistance requirements.
               uct quality safeguards long-term mechanical strength and
               corrosion resistance.


               1)  IEC 61400-24 Wind turbines – Part 24: Lightning protection
               2)  IEC 62561-1 Lightning protection system components (LPSC) – Part 1: Requirements for connection components