Multi-function Meters



        PLUG & PLAY MULTI-FUNCTION METERS


                                               DIRIS B-10
        Features:                               Description                                          Part No.
           - Global accuracy Class 0.5 associated with TE, TF,   Neutral Current Monitoring
          iTR sensors
           - Plug and play, a rapid RJ12 connection makes   DIRIS B-10 multi-function meter with RS485 Modbus   48290010
                                                Utilises Digiware current sensors
          wiring easy and reliable              Auxiliary supply: 110 - 230V AC
           - Automatic detection of CT ratios
           - Four current measurement inputs, used in single
          phase or three phase monitoring
           - Auto configuration                DIRIS B-30
           - DIN Rail mountable, 3 modules wide                                                                     2
                                                Description                                          Part No.
                                                Neutral Current Monitoring
                                                DIRIS B-30 multi-function meter with RS485 JBus/Modbus
                                                Auxiliary supply: 110 - 230V AC                      48290000



                                               STANDARD FUNCTIONS
                                                                                        B-10         B-30
                                                Multi-measurement
                                                Currents, voltages (phase/phase and phase/neutral)  •  •
                                                Active/reactive/apparent powers, frequency  •        •
                                                Voltage/current unbalance               •            •
                       48290010                 Power factor, cos ϕ, tan ϕ              •            •
                                                Metering
                                                kWh (+ /-), kvarh (+ /-), kVAh          •            •
                                                Load curves                             -            •
                                                Multi-tariff                            •            •
                                                Quality Analysis
                                                THDv, THDu, THDi                        •            •
                                                Individual harmonics V, U and I (up to rank 63)  -   •
                                                Crest factor V, U and I                 -            •
                                                Voltage dips, cut-offs and surges (EN50160)  -       •
                                                Overcurrent                             -            •
                                                Alarms
                                                On threshold                            -            •
                                                Inputs/outputs                          •            •
                                                History of Average Values
                                                45 days (maximum)                       -            •
                                                Communication
                                                RS485 Modbus                            •            •
                                                2 inputs (status/pulse)                 •            •


                                               DIRIS B ACCESSORIES
                                                Description                                          Part No.
                                                Optional Add-on Modules
                                                2 digital inputs/2 digital outputs                   48290030
                Optional Module Connection      2 analogue inputs/2 analogue outputs, 4 - 20mA       48290031
                                                3 temperature inputs PT100/PT1000                    48290032
                                                RS485 Modbus communication                           48290033
                                                PROFIBUS communication                               48290034
                                                Optional Display
                                                D-30 Single-point display                            48290200
                                                RJ9 cable for D-30 display - 1.5m                    48290280
                                                RJ9 cable for D-30 display - 3m                      48290281
                                               -  96mm x 96mm panel mount, IP65 (front panel)
                                               -  For Current Sensors, refer to page 270.
                      D-30 Display