Page 298 - IPD Product Catalog V17
P. 298

Multi-function Meters



        ABB MULTI-FUNCTION METER SELECTION CHART




                                              M1M 15                M1M 20                 M1M 30                               M4M 20                              M4M 30                            M4M 2X
         Accuracy Class                       1                     1, 0.5S (M1M 20 I/O)   1, 0.5S (M1M 30 I/O)                 0.5S                                0.5S                              0.5S
         Measured Parameter
         TRMS Current & Voltage               •                     •                      •                                    •                                   •                                 •
         Frequency                            •                     •                      •                                    •                                   •                                 •
         Active power, Power factor           •                     •                      •                                    •                                   •                                 •
         Reactive and Apparent power          •                     •                      •                                    •                                   •                                 •
         Operating timer, countdown timer     •                     •                      •                                    •                                   •                                 •
         On hours                             -                     -                      -                                    -                                   -                                 -
         Load hours                           -                     -                      -                                    -                                   -                                 -
         Active energy                        •                     •                      •                                    •                                   •                                 •
         Reactive and Apparent energy         •                     •                      •                                    •                                   •                                 •
         4 quadrants energy (Import/Export)   -                     •                      •                                    •                                   •                                 •
         Tariffs                              -                     -                      -                                    -                                   •                                 -
         Power Quality
         THD (I, VLN, VLL)                    -                     •                      •                                    •                                   •                                 •
         Individual harmonics                 -                     -                      40 th                                -                                   40 th                             25 th
         Neutral current                      -                     Calculated             Calculated                           Calculated                          Measured                          Calculated
         Phasors (I, VLN)                     -                     -                      -                                    -                                   •                                 -
         Unbalances and waveforms (I, VLN, VLL)  -                  -                      •                                    -                                   •                                 • (Unbalances)
         Measurement Accuracy
         Voltage                              Class 1 (IEC 61557-12)  Class 0.5 (IEC 61557-12)  Class 0.5 (IEC 61557-12)        Class 0.2 (IEC 61557-12)            Class 0.2 (IEC 61557-12)          Class 0.2 (IEC 61557-12)
                                              Class 1 (IEC 61557-12)
         Current                                                    Class 0.5 (IEC 61557-12)  Class 0.5 (IEC 61557-12)          Class 0.2 (IEC 61557-12)            Class 0.2 (IEC 61557-12)          Class 0.2 (IEC 61557-12)
                                              Class 1 (IEC 61557-12)  Class 1 (IEC 61557-12)  Class 1 (IEC 61557-12)
         Active power                         Class 0.5 (IEC 61557-12 )    Class 0.5 (IEC 61557-12 )    Class 0.5 (IEC 61557-12 )    Class 0.5 (IEC 61557-12)       Class 0.5 (IEC 61557-12)          Class 0.5 (IEC 61557-12)
                                              (M1M 20 I/O, M1M 30 I/O)  (M1M 20 I/O, M1M 30 I/O)  (M1M 20 I/O, M1M 30 I/O)
         Reactive power                       Class 2 (IEC 61557-12)  Class 2 (IEC 61557-12)  Class 2 (IEC 61557-12)            Class 2 (IEC 61557-12)              Class 1 (IEC 61557-12)            Class 1 (IEC 61557-12)
         Data Recording and Logs
         Single alarms                        -                     15                     15                                   25                                  25                                25
         Warnings, alarms and errors logs     -                     •                      •                                    •                                   •                                 •
         Complex alarms with logics           -                     -                      -                                    -                                   4                                 -
         Min/Max and average demand values    -                     -                      Basic                                Basic                               Advanced                          Basic
         Energy trending logs                 -                     -                      •                                    -                                   •                                 -
         RTC                                  -                     -                      •                                    -                                   •                                 •
         Voltage Measurement Inputs
         Measurement range                    80 - 265V AC (L-N)    80 - 265V AC (L-N)     80 - 265V AC (L-N)                   50 - 400V AC (L-N), 87 - 690V AC (L-L)  50 - 400V AC (L-N), 87 - 690V AC (L-L)  50 - 400V AC (L-N), 87 - 690V AC (L-L)
         Rated frequency, 50 - 60Hz
                                              •                     •                      •                                     •                                   •                                •
         HMI
         Graphs visualisation                 -                     -                      -                                    Basic                               Advanced                          -
         Notifications and password protection  •                   •                      •                                    •                                   •                                 -
         Homepage and favourite page          -                     -                      -                                    •                                   •                                 -
         Current Measurement Inputs
         Measurement range                    50mA - 6A             50mA - 6A              50mA - 6A                            10mA - 6A                           10mA - 6A                         10mA - 6A
                                              5A (Class 0.5S)       5A (Class 0.5S)        5A (Class 0.5S)                      5A (Class 0.5S)                     5A (Class 0.5S)                   5A (Class 0.5S)
         CT secondary
                                              1A (Class 1)          1A (Class 1)           1A (Class 1)                         1A (Class 0.5S)                     1A (Class 0.5S)                   1A (Class 0.5S)
         Connectivity
         Automatic integration in ABB Ability™ EDCS  -              -                      -                                    •                                   •                                 •
         Bluetooth Low Energy                 -                     -                      -                                    •                                   •                                 •
         User Interface
         LED Display                          •                     -                      -                                    -                                   -                                 -
         LED digit height (mm)                10                    -                      -                                    -                                   -                                 -
         Communication                        Modbus RTU            Modbus RTU, Modbus TCP/IP  Modbus RTU, Modbus TCP/IP        Modbus RTU, Modbus TCP/IP,          Modbus RTU, Modbus TCP/IP,        Modbus RTU, Modbus TCP/IP
                                                                                                                                PROFIBUS DP-V0, BACnet/IP           PROFIBUS DP-V0, BACnet/IP
         RJ45 Daisy Chain (Ethernet version)  -                     -                      -                                    -                                   •                                 •
         Mechanical Characteristics
                                              96 x 96 x 85          96 x 96 x 85           96 x 96 x 85                         96 x 96 x 77                        96 x 96 x 77                      96 x 96 x 77
         Overall dimensions (mm)
                                              (Depth inside the switchboard: 65mm)  (Depth inside the switchboard: 65mm)  (Depth inside the switchboard: 65mm)  (Depth inside the switchboard: 57mm)  (Depth inside the switchboard: 57mm)  (DIN Rail mounting)
         IP rating                            IP54                  IP54                   IP54                                 IP54                                IP54                              IP54
         Climatic Conditions
                                              -5°C to 55°C          -5°C to 55°C           -5°C to 55°C                         -25°C to 70°C                       -25°C to 70°C                     -25°C to 70°C
         Operating temperature
                                              (K55 according to IEC 61557-12)  (K55 according to IEC 61557-12)  (K55 according to IEC 61557-12)  (K70 according to IEC 61557-12)  (K70 according to IEC 61557-12)  (K70 according to IEC 61557-12)
                                              -25°C to 70°C         -25°C to 70°C          -25°C to 70°C                        -40°C to 85°C                       -40°C to 85°C                     -40°C to 85°C
         Storage temperature
                                              (K55 according to IEC 61557-12)  (K55 according to IEC 61557-12)  (K55 according to IEC 61557-12)  (K70 according to IEC 61557-12)  (K70 according to IEC 61557-12)  (K70 according to IEC 61557-12)
         Pollution degree                     2                     2                      2                                     2                                   2                                 2
         Standards
         Electrical safety IEC 61010-1        •                     •                      •                                    •                                   •                                 •
          298                                    1300 556 601  |  ipd.com.au  |  V17-R05
   293   294   295   296   297   298   299   300   301   302   303