Page 299 - IPD Product Catalog V17
P. 299

Multi-function Meters









 M1M 15  M1M 20  M1M 30  M4M 20              M4M 30                            M4M 2X
 Accuracy Class  1  1, 0.5S (M1M 20 I/O)  1, 0.5S (M1M 30 I/O)  0.5S  0.5S     0.5S
 Measured Parameter
 TRMS Current & Voltage  •  •  •  •          •                                 •
 Frequency  •  •  •  •                       •                                 •
 Active power, Power factor  •  •  •  •      •                                 •
 Reactive and Apparent power  •  •  •  •     •                                 •
 Operating timer, countdown timer  •  •  •  •  •                               •
 On hours  -  -  -  -                        -                                 -
 Load hours  -  -  -  -                      -                                 -                                    2
 Active energy  •  •  •  •                   •                                 •
 Reactive and Apparent energy  •  •  •  •    •                                 •
 4 quadrants energy (Import/Export)  -  •  •  •  •                             •
 Tariffs  -  -  -  -                         •                                 -
 Power Quality
 THD (I, VLN, VLL)  -  •  •  •               •                                 •
 Individual harmonics  -  -  40 th  -        40 th                             25 th
 Neutral current  -  Calculated  Calculated  Calculated  Measured              Calculated
 Phasors (I, VLN)  -  -  -  -                •                                 -
 Unbalances and waveforms (I, VLN, VLL)  -  -  •  -  •                         • (Unbalances)
 Measurement Accuracy
 Voltage  Class 1 (IEC 61557-12)  Class 0.5 (IEC 61557-12)  Class 0.5 (IEC 61557-12)  Class 0.2 (IEC 61557-12)  Class 0.2 (IEC 61557-12)  Class 0.2 (IEC 61557-12)
 Class 1 (IEC 61557-12)
 Current  Class 0.5 (IEC 61557-12)  Class 0.5 (IEC 61557-12)  Class 0.2 (IEC 61557-12)  Class 0.2 (IEC 61557-12)  Class 0.2 (IEC 61557-12)
 Class 1 (IEC 61557-12)  Class 1 (IEC 61557-12)  Class 1 (IEC 61557-12)
 Active power  Class 0.5 (IEC 61557-12 )    Class 0.5 (IEC 61557-12 )    Class 0.5 (IEC 61557-12 )    Class 0.5 (IEC 61557-12)  Class 0.5 (IEC 61557-12)  Class 0.5 (IEC 61557-12)
 (M1M 20 I/O, M1M 30 I/O)  (M1M 20 I/O, M1M 30 I/O)  (M1M 20 I/O, M1M 30 I/O)
 Reactive power  Class 2 (IEC 61557-12)  Class 2 (IEC 61557-12)  Class 2 (IEC 61557-12)  Class 2 (IEC 61557-12)  Class 1 (IEC 61557-12)  Class 1 (IEC 61557-12)
 Data Recording and Logs
 Single alarms  -  15  15  25                25                                25
 Warnings, alarms and errors logs  -  •  •  •  •                               •
 Complex alarms with logics  -  -  -  -      4                                 -
 Min/Max and average demand values  -  -  Basic  Basic  Advanced               Basic
 Energy trending logs  -  -  •  -            •                                 -
 RTC  -  -  •  -                             •                                 •
 Voltage Measurement Inputs
 Measurement range  80 - 265V AC (L-N)  80 - 265V AC (L-N)  80 - 265V AC (L-N)  50 - 400V AC (L-N), 87 - 690V AC (L-L)  50 - 400V AC (L-N), 87 - 690V AC (L-L)  50 - 400V AC (L-N), 87 - 690V AC (L-L)
 Rated frequency, 50 - 60Hz
 •  •  •   •                                  •                                •
 HMI
 Graphs visualisation  -  -  -  Basic        Advanced                          -
 Notifications and password protection  •  •  •  •  •                          -
 Homepage and favourite page  -  -  -  •     •                                 -
 Current Measurement Inputs
 Measurement range  50mA - 6A  50mA - 6A  50mA - 6A  10mA - 6A  10mA - 6A      10mA - 6A
 5A (Class 0.5S)   5A (Class 0.5S)   5A (Class 0.5S)   5A (Class 0.5S)  5A (Class 0.5S)  5A (Class 0.5S)
 CT secondary
 1A (Class 1)  1A (Class 1)  1A (Class 1)  1A (Class 0.5S)  1A (Class 0.5S)    1A (Class 0.5S)
 Connectivity
 Automatic integration in ABB Ability™ EDCS  -  -  -  •  •                     •
 Bluetooth Low Energy  -  -  -  •            •                                 •
 User Interface
 LED Display  •  -  -  -                     -                                 -
 LED digit height (mm)  10  -  -  -          -                                 -
 Communication  Modbus RTU  Modbus RTU, Modbus TCP/IP  Modbus RTU, Modbus TCP/IP  Modbus RTU, Modbus TCP/IP,  Modbus RTU, Modbus TCP/IP,  Modbus RTU, Modbus TCP/IP
         PROFIBUS DP-V0, BACnet/IP           PROFIBUS DP-V0, BACnet/IP
 RJ45 Daisy Chain (Ethernet version)  -  -  -  -  •                            •
 Mechanical Characteristics
 96 x 96 x 85   96 x 96 x 85   96 x 96 x 85   96 x 96 x 77   96 x 96 x 77      96 x 96 x 77
 Overall dimensions (mm)
 (Depth inside the switchboard: 65mm)  (Depth inside the switchboard: 65mm)  (Depth inside the switchboard: 65mm)  (Depth inside the switchboard: 57mm)  (Depth inside the switchboard: 57mm)  (DIN Rail mounting)
 IP rating  IP54  IP54  IP54  IP54           IP54                              IP54
 Climatic Conditions
 -5°C to 55°C    -5°C to 55°C    -5°C to 55°C    -25°C to 70°C   -25°C to 70°C   -25°C to 70°C
 Operating temperature
 (K55 according to IEC 61557-12)  (K55 according to IEC 61557-12)  (K55 according to IEC 61557-12)  (K70 according to IEC 61557-12)  (K70 according to IEC 61557-12)  (K70 according to IEC 61557-12)
 -25°C to 70°C    -25°C to 70°C    -25°C to 70°C    -40°C to 85°C   -40°C to 85°C   -40°C to 85°C
 Storage temperature
 (K55 according to IEC 61557-12)  (K55 according to IEC 61557-12)  (K55 according to IEC 61557-12)  (K70 according to IEC 61557-12)  (K70 according to IEC 61557-12)  (K70 according to IEC 61557-12)
 Pollution degree  2  2  2   2                2                                 2
 Standards
 Electrical safety IEC 61010-1  •  •  •  •   •                                 •
                                               1300 556 601  |  ipd.com.au  |  V17-R05                       299
   294   295   296   297   298   299   300   301   302   303   304