Page 557 - IPD Product Catalog V17
P. 557

Sensors



        PRESSURE SWITCHES - DS 200


                                                      Ordering Code DS 200
         DS 200                           -              -    -     -     -          -           -     -
         Pressure
                        Gauge in bar  (1)  7  8  0
                       Gauge in H 2 O  (1)  7  8  H
                      Absolute in bar  (2)  7  8  1
         Input     [mH 2 O]  [bar]
                      1.0     0.10  (2)      1  0  0  0
                      1.6     0.16  (2)      1  6  0  0
                      2.5     0.25  (2)      2  5  0  0
                      4.0     0.40           4  0  0  0
                      6.0     0.60           6  0  0  0
                      10       1.0           1  0  0  1
                       16      1.6           1  6  0  1
                      25       2.5           2  5  0  1
                      40       4.0           4  0  0  1
                      60       6.0           6  0  0  1
                      100      10            1  0  0  2
                      160      16            1  6  0  2
                      250      25            2  5  0  2
                      400      40            4  0  0  2
                     600       60            6  0  0  2
                              100            1  0  0  3
                              160            1  6  0  3
                              250            2  5  0  3
                              400            4  0  0  3
                              600            6  0  0  3
                              -1 - 0         X  1  0  2
                           Customer          9  9  9  9
         Analogue Output
                            Without                        0                                                        4
                      4 - 20mA / 2-wire                     1
                        0 - 10V / 3-wire                   3
                4 - 20mA / 3-wire, adjustable              7J
              Intrinsic Safety 4 - 20mA / 2-wire  (3)      E
                           Customer                        9
         Contact
                           1 Contact  (3)(4)                     1
                          2 Contacts  (3)(4)                     2
                          4 Contacts (5)                         4
         Accuracy
            Standard for P N  > 0.4bar: 0.35% FSO                      3
            Standard for P N  ≤ 0.4bar: 0.50% FSO                      5
             Option for P N  ≥ 0.4bar: 0.25% FSO                       2
                           Customer                                    9
         Electrical Connection
         Male plug M12 x 1 (5-pin) / plastic version                         N  0  1
         Male plug M12 x 1 (8-pin)/   plastic version (5)                   M   5  0
         Male plug M12 x 1 (5-pin) / metal version                           N  1  1
              Male and female plug ISO 4400  (4)                             1  0  0
            Male plug Binder Series 723 (5-pin)                              2  0  4
                Cable outlet with PVC cable  (6)                             T  A  0
                           Customer                                          9  9  9
         Mechanical Connection
                       G1/2” DIN 3852                                                   1  0  0
                         G1/2” EN 837                                                   2  0  0
                        G1/4” DIN 3852                                                  3  0  0
                         G1/4” EN 837                                                   4  0  0
             G1/2” DIN 3852 with Flush sensor (7)                                       F  0  0
             G3/4” DIN 3852 with Flush sensor (7)                                       K  0  0
                           1/2” NPT                                                     N  0  0
                           1/4” NPT                                                     N  4  0
                           Customer                                                     9  9  9
         Seal
                              FKM                                                                   1
                  Without (welded version)  (8)                                                     2
                           Customer                                                                 9
         Special Version
                           Standard                                                                      0  0  0
                           Customer                                                                      9  9  9
        (1)   From 60bar: measurement starts with ambient pressure
        (2)   Absolute pressure possible from 0.4bar
        (3)   With IS version a maximum of 1 contact is possible
        (4)  With connector ISO 4400 and output 2-wire version, a maximum of 1 contact is possible; with 3-wire version no contacts are possible.
        (5)   4 Contacts and M12 x 1, 8-pin only possible in combination and together with 4 - 20mA / 3-wire; 0 - 10V / 3-wire available on request.
        (6)   Standard: 2m PVC cable without ventilation tube (permissible temperature: -5°C to 70°C); others available on request.
        (7)   Not possible for nominal pressure P N  > 40bar; for G3/4“ flush nominal pressure absolute available on request.
        (8)  Welded version only with pressure ports according to EN 837 and NPT; possible for nominal pressure ranges P N  ≤ 40bar.

                                               1300 556 601  |  ipd.com.au  |  V17-R05                       557
   552   553   554   555   556   557   558   559   560   561   562