Page 557 - IPD Product Catalog V17
P. 557
Sensors
PRESSURE SWITCHES - DS 200
Ordering Code DS 200
DS 200 - - - - - - - -
Pressure
Gauge in bar (1) 7 8 0
Gauge in H 2 O (1) 7 8 H
Absolute in bar (2) 7 8 1
Input [mH 2 O] [bar]
1.0 0.10 (2) 1 0 0 0
1.6 0.16 (2) 1 6 0 0
2.5 0.25 (2) 2 5 0 0
4.0 0.40 4 0 0 0
6.0 0.60 6 0 0 0
10 1.0 1 0 0 1
16 1.6 1 6 0 1
25 2.5 2 5 0 1
40 4.0 4 0 0 1
60 6.0 6 0 0 1
100 10 1 0 0 2
160 16 1 6 0 2
250 25 2 5 0 2
400 40 4 0 0 2
600 60 6 0 0 2
100 1 0 0 3
160 1 6 0 3
250 2 5 0 3
400 4 0 0 3
600 6 0 0 3
-1 - 0 X 1 0 2
Customer 9 9 9 9
Analogue Output
Without 0 4
4 - 20mA / 2-wire 1
0 - 10V / 3-wire 3
4 - 20mA / 3-wire, adjustable 7J
Intrinsic Safety 4 - 20mA / 2-wire (3) E
Customer 9
Contact
1 Contact (3)(4) 1
2 Contacts (3)(4) 2
4 Contacts (5) 4
Accuracy
Standard for P N > 0.4bar: 0.35% FSO 3
Standard for P N ≤ 0.4bar: 0.50% FSO 5
Option for P N ≥ 0.4bar: 0.25% FSO 2
Customer 9
Electrical Connection
Male plug M12 x 1 (5-pin) / plastic version N 0 1
Male plug M12 x 1 (8-pin)/ plastic version (5) M 5 0
Male plug M12 x 1 (5-pin) / metal version N 1 1
Male and female plug ISO 4400 (4) 1 0 0
Male plug Binder Series 723 (5-pin) 2 0 4
Cable outlet with PVC cable (6) T A 0
Customer 9 9 9
Mechanical Connection
G1/2” DIN 3852 1 0 0
G1/2” EN 837 2 0 0
G1/4” DIN 3852 3 0 0
G1/4” EN 837 4 0 0
G1/2” DIN 3852 with Flush sensor (7) F 0 0
G3/4” DIN 3852 with Flush sensor (7) K 0 0
1/2” NPT N 0 0
1/4” NPT N 4 0
Customer 9 9 9
Seal
FKM 1
Without (welded version) (8) 2
Customer 9
Special Version
Standard 0 0 0
Customer 9 9 9
(1) From 60bar: measurement starts with ambient pressure
(2) Absolute pressure possible from 0.4bar
(3) With IS version a maximum of 1 contact is possible
(4) With connector ISO 4400 and output 2-wire version, a maximum of 1 contact is possible; with 3-wire version no contacts are possible.
(5) 4 Contacts and M12 x 1, 8-pin only possible in combination and together with 4 - 20mA / 3-wire; 0 - 10V / 3-wire available on request.
(6) Standard: 2m PVC cable without ventilation tube (permissible temperature: -5°C to 70°C); others available on request.
(7) Not possible for nominal pressure P N > 40bar; for G3/4“ flush nominal pressure absolute available on request.
(8) Welded version only with pressure ports according to EN 837 and NPT; possible for nominal pressure ranges P N ≤ 40bar.
1300 556 601 | ipd.com.au | V17-R05 557