Page 559 - IPD Product Catalog V17
P. 559
Sensors
PRESSURE SWITCHES - DS 201
Ordering Code DS 201
DS 201 - - - - - - - - - -
Pressure
Gauge in bar 7 8 2
Gauge in H 2 O 7 8 E
Absolute in bar 7 8 3
Input [mH 2 O] [bar]
4 0.4 4 0 0 0
6 0.6 6 0 0 0
10 1.0 1 0 0 1
16 1.6 1 6 0 1
25 2.5 2 5 0 1
40 4.0 4 0 0 1
60 6.0 6 0 0 1
100 10 1 0 0 2
160 16 1 6 0 2
250 25 2 5 0 2
400 40 4 0 0 2
600 60 6 0 0 2
100 1 0 0 3
160 1 6 0 3
250 2 5 0 3
400 4 0 0 3
600 6 0 0 3
-1 - 0 X 1 0 2
Customer 9 9 9 9
Analogue Output
Without 0
4 - 20mA / 2-wire 1
0 - 10V / 3-wire 3
4 - 20mA / 3-wire, adjustable 7
Intrinsic Safety 4 - 20mA / 2-wire (1) E
Customer 9 4
Contact
1 Contact (1)(2) 1
2 Contacts (1)(2) 2
4 Contacts (3) 4
Accuracy
0.5% FSO 5
Customer 9
Electrical Connection
Male plug M12 x 1 (5-pin) / plastic version N 0 1
Male plug M12 x 1 (8-pin) / plastic version (3) M 5 0
Male plug M12 x 1 (5-pin) / metal version N 1 1
Male and female plug ISO 4400 (2) 1 0 0
Male plug Binder Series 723 (5-pin) 2 0 4
Cable outlet with PVC cable (4) T A 0
Customer 9 9 9
Mechanical Connection
G1/2” DIN 3852 1 0 0
G1/2” EN 837 2 0 0
G1/4” DIN 3852 3 0 0
G1/4” EN 837 4 0 0
G1/2” DIN 3852 withsemi-flush sensor (5) F 0 0
G3/4” DIN 3852 with flush sensor (6) K 0 0
G1/2” DIN 3852 open pressure port H 0 0
1/2” NPT N 0 0
1/4” NPT N 4 0
Customer 9 9 9
Seal
FKM 1
EPDM (7) 3
Customer 9
Pressure Port
Stainless Steel 1.4404 (316L) 1
PVDF (8) B
Customer 9
Diaphragm
Ceramics Al 2 O 3 96% 2
Customer 9
Special Version
Standard 0 0 0
Oxygen application (9) 0 0 7
Customer 9 9 9
(1) With IS version, a maximum of 1 contact is possible.
(2) With connector ISO 4400 and output 2-wire version, only a maximum of 1 contact is possible; with 3-wire version no contacts are possible.
(3) 4 Contacts and M12 x 1, 8-pin only possible in combination and together with 4 - 20mA/ 3-wire; 0 - 10V / 3-wire available on request.
(4) Standard: 2m PVC cable without ventilation tube (permissible temperature: -5°C to 70 °C), others available on request.
(5) Possible for nominal pressure ranges P N ≥ 0.6bar up to P N ≤ 60bar gauge, absolute available on request.
(6) Possible for nominal pressure ranges P N ≥ 0.6bar up to P N ≤ 60bar gauge
(7) Possible for nominal pressure ranges P N ≤ 160bar
(8) PVDF only with G1/2” DIN 3852 open pressure port (up to 60bar) and G3/4” DIN 3852 with flush sensor (0.6bar ≤ P N ≤ 25 bar);
permissible medium temperature: -30°C to 60°C.
(9) Oxygen application with FKM-seal up to 25bar possible, flush version available on request.
1300 556 601 | ipd.com.au | V17-R05 559