Page 562 - IPD Product Catalog V17
P. 562
Sensors
INDUCTIVE PROXIMITY SENSORS - GX-F/H
RECTANGULAR SENSORS
Features: Stable Maximum Output
- Detects metal objects Type Sensing Sensing Operation Output Part No.
- Leading sensor range with long stable sensing Range (mm) Distance (mm)
ranges in the industry NPN GX-F6A
- Resistant to oil and water and has a protection Front Normally Open PNP GX-F6A-P
structure of IP68G Sensing NPN GX-F6B
- Orange LED indicator lights up when the Normally Closed PNP GX-F6B-P
output is ON 0 to 1.3 1.6
- Supply voltage: 12 - 24V DC ±10 % Normally Open NPN GX-H6A
- Operation temperature range: -25 °C to +70°C Top PNP GX-H6A-P
Sensing NPN GX-H6B
Normally Closed
PNP GX-H6B-P
NPN GX-F8A
Normally Open
Front PNP GX-F8A-P
Sensing NPN GX-F8B
Normally Closed
PNP GX-F8B-P
0 to 2.1 2.5
NPN GX-H8A
Normally Open
Top PNP GX-H8A-P
Sensing NPN GX-H8B
Normally Closed
PNP GX-H8B-P
NPN GX-F12A
Normally Open
Front PNP GX-F12A-P
Sensing NPN GX-F12B
GX-H6A Normally Closed
PNP GX-F12B-P
0 to 3.3 4
NPN GX-H12A
Normally Open
Top PNP GX-H12A-P
Sensing NPN GX-H12B
Normally Closed
PNP GX-H12B-P
NPN GX-F15A
Normally Open
Front PNP GX-F15A-P
Sensing NPN GX-F15B
Normally Closed
PNP GX-F15B-P
0 to 4.2 5
NPN GX-H15A
Normally Open
Top PNP GX-H15A-P
Sensing NPN GX-H15B
Normally Closed
PNP GX-H15B-P
- The stable sensing range stands for the sensing range for which the sensor can stably detect
the standard sensing object even if there is an ambient temperature drift and/or supply
voltage fluctuation.
- When ordering 5m (16.404ft) cable length type, add suffix “-C5” to the part no.