Page 16 - Reliable_System_Solutions
P. 16

insulating pipe with
 ®
 HVI  conductor
 in the hazardous area


 ®
 insulating pipe with  HVI  conductor
 ®
 HVI  conductor
 at a cell site mast                                                                                                                        HVI  conductor in  the
                                                                                                                                               ®
                                                                                                                                                  insulating pipe
 isolated air-
 termination rod                                                                                                                                 Part No. 819 320
 with tripod support
 telescopic lightning
 protection mast
 DEHNiso distance holder
 isolated air-termination rod
 with concrete base
 DEHNiso Combi

 =
 head piece

 head piece  head piece
 ®
 DEHNconductor system HVI  conductor –
 durable, universal, tried and tested.
 sealing unit  sealing unit  sealing unit
 area  area  area
 High impulse voltages cause flashovers at the surface of insulating  via an equipotential bonding connection element. The black
 ®
 materials if no additional protection measures are taken. This  coaxial HVI  conductor with an outer diameter of 20 mm and
 ®
 effect is known as creeping flashover. If the creeping discharge  the grey coaxial HVI  conductor with an outer diameter of 23
 2
 inception voltage is exceeded, a surface discharge occurs which  mm consist of a 19 mm  copper wire, a thick-walled, high-voltage
 can range over a distance of several metres without any problems.  resistant insulation and a weatherproof special external coating.
 ®
 In order to avoid creeping discharges, the HVI  conductor is  In order to prevent low-energy flashovers due to capacitive  EB connection
 ®
 equipped with a special external coating which allows for  displacement currents, the HVI  conductor can be additionally  element (fixed)
 diverting high lightning impulse voltages to a reference potential.  connected to the equipotential bonding structure during  EB connection  EB connection
 In the sealing unit area, the external special coating is connected  conductor installation. These connections do not have to be  element (fixed)  element (fixed)
 to the equipotential bonding structure of the building where  capable of carrying lightning currents as the capacitive
 no parts of the lightning current flow, e.g. at earthed metal  displacement currents have low energy and do not cause
 roof superstructures in the protection zone of the lightning  dangerous sparking. Extensive measurements show that the
 ®
 ®
 ®
 protection system, at earthed parts of the building construction  HVI  conductor with its high electric strength has an equivalent  HVI  conductor  sealing unit  HVI  conductor
 which are free of lightning currents or at the protective conductor  separation distance of s = 0.75 m (air).  with special  area  with special
 of the low-voltage system. Under certain conditions, the special  coating  coating
 coating can be connected to parts of the lightning protection  heat-shrinkable
 system such as air-termination system and other down-conductors.  sleeve (not fixed)
 For this purpose, it has to be ensured that the calculated
 separation distance does not exceed 35 cm in air at the contact  earth connection element
 (not fixed)
 point. In this case, the special external coating has to be directly
 connected to the part through which lightning potential flows
 EB connection element
 earth  (not fixed)
 connection
 element (not
 fixed)  head
 piece


 ®
                                                                                                                ®
 ®
 ®
 HVI  conductor I  HVI  conductor II  HVI  conductor III                                                     HVI  conductor and
 Part No. 819 020  Part No. 819 024  Part No. 819 022                                                         insulating pipe for
                                                                                                                  biogas plants
                                                                                                                Part No. 819 750



                                                                                        distance holder for insulating
 For more technical information, please refer to the Lightning Protection main catalogue 2007  pipes at omnidirectional
 as from page 49 and to installation instructions 1566.                                 antennas
                                                                                        Part No. 105 363
   11   12   13   14   15   16   17   18   19   20   21