radius = 45 m

                                                                                                                                                                                                                                           S
                                                                                                                                                                                                                                           3 (k m  1)                   +24.5 m top edge roof superstructure
                                                                                                                                                                                                                        mesh
                                                                                                                                                                                                                                L = 5 m                    h = 2.5 m
                                                                                                                                                                                                                                                            1
                                                                                                                                                                                                                                1
                                                                                                                                                                                                                                      S
                                                                                                                                                                                                                                      2 (k m  0.5)            +22 m top edge of the roof
                                                                                                                                                                                                                                             between roof     S top edge of the roof
                                                                                                                                                                                                                                             superstructure    1
                                                                                                                                                                                                                                             and air-termination
                                                                                                                                                                                                                                             rod
                                                                                                                                                                                                                                                             down-conductor
                                                                                                                                                                                                                                                             n = 4


                                                                                                                                                                                                                                                                        15 m
                                                                                                                                                                                                                                17 m
                                                                                                                                                                                                                              building



                                                                                                                                                                                                                                    Design procedure
                                                                    Isolated air-termination systems for protecting roof

                                                                    superstructures in consideration of standards concerning
                                                                    the observance of separation distances




                                                                    According to the state of the art of lightning protection systems,                                                     Building data                                         Step 1:
                                                                    large roof superstructures should be protected by isolated air-                                                        Building height:             h = 22 m
                                                                    termination systems in case of direct lightning strokes. Electrical                                                    Number of down-conductors:   n = 4 units              Determine the length of the aluminium air-termination rod
                                                                    isolation of the lightning protection system from conductive                            !                              Height of roof superstructure:  h 1  = 2.5 m          via the protective angle method or rolling sphere method.
                                                                    parts of the building construction (metal construction parts,                                                          Class of LPS:                III                      Step 2:
                                                                    reinforcement, etc.) and isolation from electrical conductors in                                                       Building length:             17 m (maximum distance
                                                                    the building prevent lightning currents from flowing through                                                                                        between down-conductors  Calculate the separation distance to determine the position
                                                                    control and supply lines as well as interference / destruction of                                                                                   c = 17 m)                of the air-termination rod.
                                                                    sensitive electrical and electronic installations.                                                                     Building width:              15 m

                                                                    In accordance with the current DIN EN 62305-3 standard, air-                                                           The roof superstructure is supposed to be protected by an
                                                                    termination rods and/or elevated air-termination systems (ring  Roof superstructure directly connected to the air-termination system!!!  isolated air-termination rod.
                                                                    conductors or spanned cables) should be installed taking the
                                                                    calculated separation distance into account in order to protect                                                        1. Calculation k c (building):                        4. Comparison s   3 (k m  1)
                                                                    roof superstructures on buildings against lightning strokes.                                                                                                                    between roof superstructure and
                                                                    Three methods can be used for the determining the arrangement                                                             k c =   1             3  c
                                                                    and position of air-termination systems:                                                !                                      2 • n   + 0.1 + 0.2 •   h                        air-termination rod (k 1):
                                                                                                                                                                                                                                                                            m
                                                                    – Rolling sphere method                                                                                                         1                3  17                          s 3 (k m  1) = s’ 2 (L1)   + s 1
                                                                    – Protective angle method                                                                                                 k c =   2 • 4   + 0.1 + 0.2 •   22   = 0.41
                                                                    – Mesh method.                                                                                                                                                                                 1
                                                                                                                                                                                                                                                    s’ 2  (L1)  = 0.04 •    • (5 + 2.5) = 0.60 m
                                                                                                                                                                                                                                                                  0.5
                                                                    The mesh size, the radius of the rolling sphere and the protective                                                     2. Calculation of s top edge of the roof
                                                                                                                                                                                                               1
                                                                    angle depend on the class of LPS. The rolling sphere method as                                                            (side strike):                                        s 3 (k m  1) =  0.60 m + 0.72 m  = 0.66 m
                                                                    universal design method should be used particularly for           is not maintained!!!                                                                                                         2
                                                                    geometrically complicated applications. A risk analysis in
                                                                    accordance with DIN EN 62305-2 has to be carried out to                                                                   s = k i   •   k c   • L (m)                                                  with s
                                                                                                                                                                                                                                                 5. Comparison s 2  (k m  0.5)    3 (k m  1)
                                                                    determine the class of LPS. When using the protective angle                                                                       k m
                                                                    method, the protective angle of an air-termination system                                                                                                                       s 2 (k m  0.5) = 1.12 m > s 3 (k m  1) = 0.66
                                                                    depends on the selected class of LPS of the lightning protection                                                          s 1 = 0.04 •  0.41  • 22 = 0.72 m
                                                                    system and the height of the air-termination system above the                                                                        0.5
                                                                    area to be protected.                                                                                                  3. Calculation of s  between roof                     Legend:  n = total numer of down-conductors
                                                                                                                                                                                                               2
                                                                                                                                                                                              superstructure and air-termination rod                     c = maximum distance between one down-conductor and the next
                                                                                                                                                                                                                                                         h = distance (or height) between ring conductors.
                                                                                                                                                                                             (k  0.5):
                                                                                                                                                                                                m
                                                                                                                                           ok                                                                1
                                                                                                                                                                                              s 2  (L1)  = 0.04 •    • 5 = 0.40 m
                                                                                                                                       is maintained!!!                                                     0.5
                                                                                                                                                                                                                 s
                                                                                                                                                                                              s 2 (k m  0.5) = s 1   s 2  (L1)   2  = 0.72 m + 0.40 m = 1.12 m  Calculation programmes under www.dehn.de
                                                                                                                                                                                                          +
   21   22   23   24   25   26   27   28   29