Page 448 - ABB_Motor _Protection_and_Control_catalogue_20221216
P. 448
3/372 ABB MOTOR PROTECTION AND CONTROL
—
AF09 ... AF96 3-pole contactors
Terminal marking and positioning
AF09 ... AF96 contactors - AC / DC operated
03
Standard devices without addition of auxiliary contacts
A1 A2 A1 A2 A1 A2
1L1 3L2 5L3 13 1L1 3L2 5L3 21 1L1 3L2 5L3
NO NC
A1 1L1 3L2 5L3 13 A1 1L1 3L2 5L3 21 A1 1L1 3L2 5L3
NO NC
NO NC
2T1 4T2 6T3 14 2T1 4T2 6T3 22 2T1 4T2 6T3
A1 A2 A1 A2 A1 A2 A2 2T1 4T2 6T3 NO A2 2T1 4T2 6T3 NC A2 2T1 4T2 6T3
22
14
AF09 ... AF16..-30-10 (1) AF09 ... AF16..-30-01 (1) AF26 ... AF96..-30-00 (1) AF09 ... AF16..-30-10 (1) AF09 ... AF16..-30-01 (1) AF26 ... AF96..-30-00 (1)
A1 1L1 3L2 5L3 13 21 31 43 A1 1L1 3L2 5L3 13 21
NO NC NC NO NO NC
A1 A2 A1 A2 A1 A2 A1 A2
NO NC NC NO NO NC
1L1 3L2 5L3 1L1 3L2 5L3 1L1 3L2 5L3 NO 1L1 3L2 5L3 A2 2T1 4T2 6T3 14 22 32 44 A2 2T1 4T2 6T3 14 22
13X
13 21 31 43 13 21 31 43 13 21 21X AF09 ... AF96..-30-22 AF26 ... AF38..-30-11
NC
NO NC NC NO NO NC NC NO NO NC
NC
A1 1L1 3L2 5L3 13X 21X
14 22 32 44 14 22 32 44 14 22 22X NO NC
14X
2T1 4T2 6T3 2T1 4T2 6T3 2T1 4T2 6T3 NO 2T1 4T2 6T3
A1 A2 A1 A2 A1 A2 A1 A2 NO NC
A2 2T1 4T2 6T3 14X 22X
AF09 ... AF16..-30-22 AF26 ... AF96..-30-22 AF26 ... AF38..-30-11 AF40 ... AF96..-30-11 AF40 ... AF96..-30-11
Other possible contact combinations with auxiliary contacts added by the user
A1 1L1 3L2 5L3 13 21
A1 A2 A1 A2 A1 A2 A1 A2 NO NC
1L1 3L2 5L3 13 1L1 3L2 5L3 13 1L1 3L2 5L3 1L1 3L2 5L3
NO NO
21 2- -1 13 21 1- 2- -3 -1 A2 2T1 4T2 6T3 NO NC
22
14
NC = + NC NO NC = + NO + NC Combination 11
22 2- -2 14 22 1- 2- -4 -2
NO NO
2T1 4T2 6T3 14 2T1 4T2 6T3 14 2T1 4T2 6T3 2T1 4T2 6T3
A1 A2 A1 A2 A1 A2 A1 A2
Combination 11 = AF09 ... AF16..-30-10 + CA4-01 (1) Combination 11 = AF26 ... AF96..-30-00 + CA4-10 + CA4-01 (1)
A1 1L1 3L2 5L3 13 21 33
A1 A2 A1 A2 NO NC NO
1L1 3L2 5L3 13 1L1 3L2 5L3 13 1L1 3L2 5L3 13 1L1 3L2 5L3 13
NO NO NO NO
A1 21 33 A1 21 33 21 31 43 53 21 31 43 53 A2 2T1 4T2 6T3 NO 14 NC NO
22
34
NC NO = + NC NO NC NC NO NO = + NC NC NO NO Combination 21
22 34 A2 22 34 A2 22 32 44 54 22 32 44 54 A1 1L1 3L2 5L3 13 21 31 43 53
NO NO NO NO NO NC NC NO NO
2T1 4T2 6T3 14 2T1 4T2 6T3 14 2T1 4T2 6T3 14 2T1 4T2 6T3 14
A1 A2 A1 A2 NO NC NC NO NO
A2 2T1 4T2 6T3 14 22 32 44 54
Combination 21 = AF09 ... AF16..-30-10 + CAT4-11M Combination 32 = AF09 ... AF16..-30-10 + CA4-22M (1)
Combination 32
A1 A2 A1 A2
NO 1L1 3L2 5L3 13 NO 1L1 3L2 5L3 13
13X NO 13X NO
21X 21X
NC NC
= +
NC NC
A1 1L1 3L2 5L3 13 13X 21X
22X 22X NO NO NC
14X NO 14X NO
NO 2T1 4T2 6T3 14 NO 2T1 4T2 6T3 14
A1 A2 A1 A2 NO NO NC
A2 2T1 4T2 6T3 14 14X 22X
Combination 21 = CAL4-11 + AF09 ... AF16..-30-10 (1) Combination 21
Note: only AF..Z contactor with DC control voltages 12...20 V DC (coil 20) and 24 V DC (coil 30) need to respect the connection polarities indicated close to the coil terminals:
A1+ for the positive pole and A2- for the negative pole.
(1) For AF09..K ... AF38..K contactors with Push-in Spring terminals, terminal marking and positioning are the same.