Page 197 - Contactors_Catalogue
P. 197
ABB MOTOR CONTROL AND PROTECTION FOR ROLLING STOCK APPLICATIONS 3/145
—
Voltage code table
The below tables indicate the available voltage ranges Uc min. ... Uc max. usually used in rolling stock application according
to IEC 60077 standard. When placing an order, please check the required control supply and select the corresponding
AF..(Z)B / NF(Z)B control voltage range. Select a standard contactor from ordering detail pages. Change the coil voltage
code in the order code according to the table below. Example: for contactor AF09ZB-30-10 and coil 48 ...130 V DC, type is
AF09ZB-30-10-22 and order code is 1SBL136061R2210.
03
DC operated
Control supply Rated control circuit voltage Coil code
Uc min. ... Uc max. Uc min. ... Uc max. AF09..ZB(..K) ...AF38..ZB(..K) AF45 ... AF95B AF116B ... AF370B
acc. to IEC 60077 acc. to IEC 60947-4-1 NFZB(..K)
0.85 Uc min. ... 1.1 Uc max.
V DC V DC
17...32
23...42.5
23...44.5 21 72 11
25...45 20...60
33...60
36...65
42...78
50...90
55...96 48...130 22 69 12
63...113
67...120
77...143
87.5...162.5
90...150
105...183 100...250 23 70 13
120...167
152...264
187...253
AC operated
Rated control circuit voltage Coil code
Uc min. ... Uc max. AF09..(Z)B(..K) ...AF38..(Z)B(..K) AF45 ... AF95B AF116B ... AF370B
acc. to IEC 60947-4-1 NF(Z)B(..K)
0.85 Uc min. ... 1.1 Uc max.
V AC 50/60 Hz
21 — 11
24...60
48...130 22 69 12
100...250 23 70 13
250...500 14 — 14
1SBC100154S0201 1SBC100154S0201