ABB MOTOR CONTROL AND PROTECTION FOR ROLLING STOCK APPLICATIONS 3/147
AF116B ... AF370B 3 and 4-pole contactors
DC operated
Auxiliary contacts
N.O. N.C.
Type Order code Rated control circuit voltage Supply control voltage
AF116 B - 30 - 22 - 12 1SFL427063R 12 22 Uc min. ... Uc max. Uc
acc. to IEC 60947-4-1
acc. to IEC 60077
0.85 Uc min. ... 1.1 Uc max. 03
DC DC
N.O. N.C. 11 20...60 V 24 V
Main contacts 33 V
Designed for Terminal connection 48 V
rolling stock Blank: for standard ferrules Coil code 12 48...130 V 72 V
96 V
110 V
13 100...250 V 220 V
Note: For AC 50/60 Hz sinusoïdal control supply in rolling
stock application. Max. permitted control voltage must
not be exceeded during voltage fluctuation defined
acc. to IEC 60077 or EN 50155 (see technical data).
AC operated
Auxiliary contacts
N.O. N.C. Rated control circuit
Type Order code voltage
AF116 B - 30 - 22 - 13 1SFL427063R 13 22 Uc min. ... Uc max.
acc. to IEC 60947-4-1
0.85 Uc min. ... 1.1 Uc max.
AC 50/60 Hz
N.O. N.C. 11 24...60 V
Main contacts 12 48...130 V
Designed for Terminal connection Coil code 13 100...250 V
rolling stock Blank: for standard ferrules 14 250...500 V
Note: For AC 50/60 Hz sinusoïdal control supply in rolling
stock application. Max. permitted control voltage must
not be exceeded during voltage fluctuation defined
acc. to IEC 60077 or EN 50155 (see technical data).
NF(Z)B contactor relays
DC operated
Type Order code Rated control circuit voltage Supply control voltage
NF Z B - 22 - E - 22 1SBH136061R 22 22 Uc min. ... Uc max. Uc
acc. to IEC 60947-4-1
acc. to IEC 60077
0.85 Uc min. ... 1.1 Uc max.
DC DC
N.O. N.C. 21 20...60 V 24 V
Auxiliary con- Rated control circuit voltage coil code 33 V
tacts
48 V
Designed for Terminal connection Coil code 22 48...130 V 72 V
rolling stock Blank: Screw terminals for standard ferrules 96 V
K: Push-in Spring terminals for standard ferrules 110 V
Low consump- 23 100...250 V 220 V
tion
Note: For AC 50/60 Hz sinusoïdal control supply in roll-
ing stock application. Max. permitted control voltage
must not be exceeded during voltage fluctuation defined
acc. to IEC 60077 or EN 50155 (see technical data).
AC operated
Type Order code Rated control circuit voltage
NF Z B - 22 - E - 22 1SBH136061R 23 22 Uc min. ... Uc max.
acc. to IEC 60947-4-1
0.85 Uc min. ... 1.1 Uc max.
AC 50/60 Hz
N.O. N.C.
Auxiliary con- Rated control circuit voltage coil code 21 24...60 V
tacts 22 48...130 V
Designed for Terminal connection Coil code 23 100...250 V
rolling stock Blank: Screw terminals for standard ferrules 14 250...500 V
K: Push-in Spring terminals for standard ferrules
Low consumption Note: For AC 50/60 Hz sinusoïdal control supply in rolling 1SBC100154S0201 1SBC100154S0201
stock application. Max. permitted control voltage must
not be exceeded during voltage fluctuation defined
acc. to IEC 60077 or EN 50155 (see technical data).