Page 199 - Contactors_Catalogue
P. 199

ABB  MOTOR CONTROL AND PROTECTION FOR ROLLING STOCK APPLICATIONS                 3/147












          AF116B ... AF370B 3 and 4-pole contactors

          DC operated
                        Auxiliary contacts
                          N.O.    N.C.
          Type                                 Order code                      Rated control circuit voltage  Supply control voltage
          AF116   B - 30 - 22     - 12          1SFL427063R 12 22              Uc min. ... Uc max.  Uc
                                                                               acc. to IEC 60947-4-1
                                                                                                   acc. to IEC 60077
                                                                               0.85 Uc min. ... 1.1 Uc max.           03
                                                                               DC                  DC
                     N.O.    N.C.                                            11   20...60 V        24 V
                    Main contacts                                                                  33 V
                     Designed for  Terminal connection                                             48 V
                     rolling stock  Blank: for standard ferrules     Coil code  12   48...130 V    72 V
                                                                                                   96 V
                                                                                                   110 V
                                                                             13   100...250 V      220 V
                                                                             Note: For AC 50/60 Hz sinusoïdal control supply in rolling
                                                                             stock application. Max. permitted control voltage must
                                                                             not be exceeded during voltage fluctuation defined
                                                                             acc. to IEC 60077 or EN 50155 (see technical data).
          AC operated
                        Auxiliary contacts
                          N.O.    N.C.                                         Rated control circuit
          Type                                 Order code                      voltage
          AF116   B - 30 - 22     - 13          1SFL427063R 13 22              Uc min. ... Uc max.
                                                                               acc. to IEC 60947-4-1
                                                                               0.85 Uc min. ... 1.1 Uc max.
                                                                               AC 50/60 Hz
                     N.O.    N.C.                                            11   24...60 V
                    Main contacts                                            12   48...130 V
                      Designed for  Terminal connection              Coil code  13   100...250 V
                      rolling stock  Blank: for standard ferrules            14   250...500 V
                                                                             Note: For AC 50/60 Hz sinusoïdal control supply in rolling
                                                                             stock application. Max. permitted control voltage must
                                                                             not be exceeded during voltage fluctuation defined
                                                                             acc. to IEC 60077 or EN 50155 (see technical data).

          NF(Z)B contactor relays

          DC operated
          Type                                 Order code                      Rated control circuit voltage  Supply control voltage
          NF Z    B - 22 - E     - 22          1SBH136061R 22 22               Uc min. ... Uc max.  Uc
                                                                               acc. to IEC 60947-4-1
                                                                                                  acc. to IEC 60077
                                                                               0.85 Uc min. ... 1.1 Uc max.
                                                                               DC                 DC
                     N.O.    N.C.                                            21   20...60 V         24 V
                    Auxiliary con-      Rated control circuit voltage coil code                     33 V
                      tacts
                                                                                                    48 V
                     Designed for  Terminal connection                Coil code  22  48...130 V     72 V
                     rolling stock  Blank: Screw terminals for standard ferrules                   96 V
                                   K: Push-in Spring terminals for standard ferrules               110 V
                  Low consump-                                               23   100...250 V       220 V
                  tion
                                                                             Note: For AC 50/60 Hz sinusoïdal control supply in roll-
                                                                             ing stock application. Max. permitted control voltage
                                                                             must not be exceeded during voltage fluctuation defined
                                                                             acc. to IEC 60077 or EN 50155 (see technical data).
          AC operated
          Type                                 Order code                      Rated control circuit voltage
          NF Z    B - 22 - E     - 22          1SBH136061R 23 22               Uc min. ... Uc max.
                                                                               acc. to IEC 60947-4-1
                                                                               0.85 Uc min. ... 1.1 Uc max.
                                                                               AC 50/60 Hz
                     N.O.    N.C.
                    Auxiliary con-     Rated control circuit voltage coil code  21   24...60 V
                      tacts                                                  22   48...130 V
                     Designed for  Terminal connection               Coil code  23  100...250 V
                     rolling stock  Blank: Screw terminals for standard ferrules  14   250...500 V
                                   K: Push-in Spring terminals for standard ferrules
                  Low consumption                                            Note: For AC 50/60 Hz sinusoïdal control supply in rolling   1SBC100154S0201 1SBC100154S0201
                                                                             stock application. Max. permitted control voltage must
                                                                             not be exceeded during voltage fluctuation defined
                                                                             acc. to IEC 60077 or EN 50155 (see technical data).
   194   195   196   197   198   199   200   201   202   203   204