5/32             ABB  MOTOR CONTROL AND PROTECTION FOR ROLLING STOCK APPLICATIONS

          —
          MCR 4-pole mini contactor relays

          Technical data




          Mounting characteristics and conditions for use
          Contactor types           DC operated MCRC
          Mounting positions                      Pos. 2
                                                           + 30°  - 30°

                                            Pos. 4
                                                       Pos. 3
                                                   Pos. 1      Pos. 1 ± 30°  Pos. 5  Pos. 6

          Mounting distances                The contactors can be assembled side by side.
          Fixing
              On rail acc. to IEC/EN 60715  35 x 7.5 mm or 35 x 15 mm
              By screws (not supplied)      4 screws at the 4 angles - M4
          Connection characteristics
          Terminals



                                             Screw terminals with cable clamp  Conductors with insulated ring tongue ferrule
          Connection capacity
            Auxiliary terminals
                   Rigid: solid            1 x 0.75 ... 4 mm²                  –
                                           2 x 0.75 ... 2.5 mm²                –
   05
                   Flexible without ferrule  1 or 2 x 0.75 ... 2.5 mm²         –
                   Flexible with ferrule   1 x 0.75 ... 2.5 mm²                –
                   (insulated or not)      2 x 0.75 ... 1.5 mm²                –
                   Lugs                 Ø mm > –                               3.6 mm
               ø  L
                                        L mm < –                               6.6 mm
            Connection capacity acc. to UL/CSA  1 or 2 x AWG 12 ... 18         –
            Stripping length                 9 mm                              –
            Tightening torques               0.8 ... 1.0 Nm / 7 lb.in          0.8 Nm / 7 lb.in
            Coil terminals
                   Rigid: solid         1 or 2 x 0.75 ... 2.5 mm²              –
                   Flexible without ferrule  1 or 2 x 0.75 ... 2.5 mm²         –
                   Flexible with ferrule   1 x 0.75 ... 2.5 mm²                –
                   (insulated or not)      2 x 0.75 ... 1.5 mm²                –
                   Lugs                 Ø mm > –                               3.6 mm
               ø  L
                                        L mm < –                               6.6 mm
            Connection capacity acc. to UL/CSA  1 or 2 x AWG 12 ... 18         –
            Stripping length                 9 mm                              –
            Tightening torques               0.8 Nm / 7 lb.in
          Degree of protection acc. to IEC/EN 60947-1 and IEC/EN 60529
            All terminals                    IP20
          Screw terminals                    (screws of unused terminals must be tightened)
            All terminals                    M3                                M3.5
          Screwdriver type                   Flat Ø 5.5 mm / Pozidriv 2














                                                                                                                 2CDC102085C0201 - Rev. A