Page 8 - DEHN-protects-technical-building-equipment_DS197_E
P. 8

Lightning equipotential protection bonding /

            surge protection


            Consistent lightning equipotential bonding is an important basis for the safe func-
            tioning of the entire lightning protection system. For an effective surge protection                                                                       3
            concept, it is important to ensure that the three-stage protection principle is ob-
            served.



            The consequences of a lightning strike are particularly   Three-stage protection principle
            serious in buildings designed in accordance with Industry   In addition to taking the different lightning protection zones                                                          2                                5
            4.0, in systems for renewable energy generation or in   into account, an effective surge protection concept is also
            systems with a modern building infrastructure. It is not only   based on three protection stages, in which the incoming     4
            a matter of destroying valuable system technology, but also   energy is gradually reduced to a low level that is safe for         1
            of damage resulting from the interruption of operations   terminal devices:                                                                          6   7
            such as failure of work processes, IT systems and manufac-                                                                                                                                                                  6  7
            turing systems. An important basis for the necessary system   ƒ Stage 1: Type 1 lightning current arresters / combined                                                                              5   7
            availability of such modern building equipment as well as for   arresters at the entrance point into the building (lightning
            the safe functioning of the entire lightning protection   equipotential bonding).
            system is a consistent lightning equipotential bonding for all   ƒ Stage 2: Type 2 surge arresters usually installed in the
            electrical cables entering the building from outside.
                                                                downstream sub-distribution boards.                                  Lightning equipotential bonding / surge potection  Application / interface  Type        Part No.
            Lightning equipotential bonding (according to IEC 62305-3)   ƒ Stage 3: Type 3 surge arresters, which can be installed
            is an extension of protective equipotential bonding accor-  directly at the terminal device or in socket outlets.       1                    DEHNvenCI 1 255 FM           Power supply line      DVCI 1 255 FM   961 205
            ding to IEC 60364-4-41. In addition to all those extraneous                                                                                  Spark-gap-based combined arrester   230 / 400 V
                                                                                                                                                         with integrated lightning current
            conductive parts which are directly connected to the   Interaction of the individual protection stages ensures the                           arrester backup fuse.
            equipotential bonding, the lightning equipotential bonding   best possible protective effect. To this end, the relevant
            must also encompass the supply lines of the network   arresters must be energy coordinated according to
            operator, communication lines and other electrical interfaces   IEC 60364-5-53 clause 534.
            and systems which inject lightning currents into the                                                                    2                    LSA-plus technology          Telecommunication line  DRL 10 B 180 FSD  907 401
            building. The connection must be made as closely as                                                                                          Modular system of lightning current                 EF 10 DRL       907 498
                                                                                                                                                         and surge arresters, can be combined
            possible to the entrance point into the building by way of                                                                                   to a single combined arrester.                      DRL PD 180      907 430
            type 1 lightning current arresters.
                                                                                                                                    3                    DEHNgate                     SAT system / radio-relay   DGA GFF TV  909 705
                                                                                                                                                         The DEHNgate GFF TV combined arres-  system / BOS (emergency
                                                                                                                                                         ter protects the SAT system / radio-relay   service) radio
                                                                                                                                                         antenna at the entrance point into the
                           Type 1                          Type 2                          Type 3                                                        building.
                  lightning current arrester            surge arrester                 surge arrester
                                                                                                                                    4                    High-performance isolating spark   Gas network      TFS             923 023
                                                                                                                                                         gap
                                                                                                                                                         For indirect connection/earthing of
                                                     Sub-distribution board                                                                              functionally isolated system parts.
                     Main distribution board                terminal device           Terminal device
                                                                                                                                    5                    DEHNshield TNS               AC-supplied charging post or   DSH TNS 255  941 400
                                                                                                                                                         Allows compact lightning equipotential   outdoor lighting system
                                                                                                                                                         bonding including protection of termi-  230 / 400 V
                                                                                                                                                         nal devices.                 Supply line


                                                                                                                                    6                    DEHNshield TN                Power supply toll barrier  DSH TN 255  941 200
                                                                                                                                                         Prewired, application-optimised
                                                                                                                                                         combined arrester for single-phase TN
                                                                                                                                                         systems.

                                                                                                                                    7                    BLITZDUCTORconnect           Data and communication line  BCO ML2 BD 24  927 244
                                                                                                                                                         Space-saving, modular combined arres-
                                                                                                                                                                                      Charging post or toll barrier
                         6/4 kV                           4/2.5 kV                        ≤ 1.5 kV                                                       ter with a width of 6 mm and push-in
                                                                                                                                                         connection technology.
              Example of a three-stage protection concept



                                                                                                                             More information at:       Use our online configurators
                                                                                                                             de.hn/configurators        for easy and fast selection



      8                                                                                                                                                                                                                                  9
   3   4   5   6   7   8   9   10   11   12   13