Page 1916 - Din prodcuts 2020
P. 1916

14/102           ELECTRICAL INSTALL ATION SOLUTIONS FOR BUILDINGS   2CHC 420 001 C0201




          —
          ABB i-bus® KNX
          Automation, Logic and Time Control




                                    Logic Module, MDRC
                                    Used to solve a varied range of project-specific control tasks and can implement 3 functions
                                    simultaneously. The following functions are available for selection: logic gate, filter, time de-
                                    lay, multiplier, min/max value detector, temperature comparator, toggle values, threshold
                                    detection, format converter, scenes, increment/decrement values, staircase lighting.

                                    Description          Mod.  Order details                Price Weight  Pack
          LM/S 1.1                                       width                             1 piece 1 piece  unit
                                                              Type code     Order code           kg      pc.
                                                         2    LM/S 1.1      GHQ6310080R0111      0.1     1


                                    Application Unit Logic, MDRC
                                    Allows the compilation of complex logical functions by simply combining different logic ele-
                                    ments and gates using a graphical user interface as an ETS plug-in and does not require ad-
                                    ditional software. 50 logical elements, 50 gates, 30 timer modules and 10 comparators are
                                    available.


                                    Description          Mod.  Order details                Price Weight  Pack
                                                         width                             1 piece 1 piece  unit
          ABL/S 2.1
                                                              Type code     Order code           kg      pc.
                                                         2    ABL/S 2.1     2CDG110073R0011      0.12    1


                                    Application Unit Time, MDRC
                                    It provides a yearly time clock program with 15 daily routines (800 switching events), a
                                    weekly schedule and allowance for 100 special days. Additionally, the unit can control up to
                                    300 participants in 30 macro groups, that can be triggered using a single command. In this
                                    way, each time controlled switching event can cause a series of actions. The switching times
                                    can be modified with the free PZM software without using ETS. PZM Software and addi-
                                    tional information on www.abb.com/knx.
  14
          ABZ/S 2.1
                                    Description          Mod.  Order details                Price Weight  Pack
                                                         width                             1 piece 1 piece  unit
                                                              Type code     Order code           kg      pc.
                                                         2    ABZ/S 2.1     2CDG110072R0011      0.12    1


                                    Logic Controller, MDRC
                                    The device provides extensive logic functions. The logic is defined via a graphic editor inte-
                                    grated in the ETS. Up to 3000 logic gates are possible.
                                    The generated logic can be tested by a simulation function. User-defined function blocks
                                    can be created and saved for taking them over into other projects.
                                    The device requires an auxiliary voltage, either 24 V DC or Power over Ethernet (PoE). If timer
                                    functions are used the date and time has to be provided via KNX/TP.

          ABA/S 1.2.1
                                    Description          Mod.  Order details                Price Weight  Pack
                                                         width                             1 piece 1 piece  unit
                                                              Type code     Order code           kg      pc.
                                                         2    ABA/S 1.2.1   2CDG110192R0011      0.192   1
   1911   1912   1913   1914   1915   1916   1917   1918   1919   1920   1921