4/66             ELECTRICAL INSTALL ATION SOLUTIONS FOR BUILDINGS   2CHC 420 001 C0201




          —
          Auxiliary elements for S800
          S800-AUX




  4
                                    S800-AUX
                                    Auxiliary contact for external display
                                    The S800-AUX auxiliary contact is for electrical display of the operating state of the high
                                    performance MCB. Both changeover contacts always switch simultaneously with the live
                                    conductor contact and detect the following operating states:
                                    •  Manual tripping
                                    •  Tripping due to thermal overload
                                    •  Tripping due to magnetic overload (short-circuit)

                                    Mode of function of the test button
                                    The test button is operated by a tool and allows the user to simulate the mode of function of
                                    the auxiliary contact when switched on without tripping the high performance MCB itself.

                                    Mode of function of the two changeover contacts
                                    •  Off position of the high performance MCB      contacts 11–12 and 21–22 closed
                                    •  On position of the high performance MCB      contacts 11–14 and 21–24 closed

                                    Mounting ability of the auxiliary contact
                                    •  Two S800-AUX auxiliary contacts can be mounted by the user at the left on the high
                                       performance MCB.


                                    Auxiliary contact S800-AUX
                                    Utilisation categories                 AC15 400/2 A, AC15 240/6 A, DC13 250/0.55 A,
                                    compliant to IEC 60947-5-1             DC13 125 V/1.1 A, DC13 60 V/2 A, DC13 24 V/4 A
                                    Rated values compliant to UL 489       125 VAC/6 A, 250 VAC/5 A, 24 V DC/4 A,
                                                                           125 V DC/0.3 A, 250 V DC/0.15 A
                                    Conventional free air thermal current I th  A  6
                                    Minimum operational current I  mA      3
                                                        min
                                    Minimum operational voltage U min  V   24
                                    Rated insulation voltage U i   V       690
                                    Number of contacts                     2
                                    Rated impulse withstand voltage U  kV  6
                                                            imp
                                    Pollution degree                       3
                                    Standard                               IEC 60947-5-1 / UL 489
                                    Contact function                       Changeover contact
                                    Connection C   u               mm 2    1 x 2.5
                                                                           2 x 1.5
                                                                           14 AWG
                                    Tightening torque              Nm      1
                                    AC/DC feed                             any
                                    Mounting on DIN top hat rail           EN 60715
                                    Protection category                    IP20
                                    Permissible operating ambient temperature °C   -25 ... +60
                                    Storage temperature            °C      - 40 ... +70
                                    Mech. lifetime of device               6000 switching cycles
                                    I                              A       1000
                                    cu
                                    Vibration resistance                   IEC 60068-2-6;
                                                                           EN 61373 Cat.1/Class B
                                                                           5 g, 20 frequency cycle
                                                                           5 ... 150 ... 5 Hz
                                                                           at 24 V AC/DC, 5 mA short-term interruption <10 ms

                                                           GTIN    Order details               Price  Weight Pack
                                                           761227                              1    1 piece unit

                                    Article                EAN     Type code   Order code      piece  kg  pc.