Page 697 - Din prodcuts 2020
P. 697

6/65




          —
          Command and signaling
          Transformers selection table




 Bell      Safety                    Control                  Control and Safety       Control and Isolating
 transformers  transformers          transformers             transformers             transformers
 for discontinuous use  for general use  for general use      for general use          for general use




                                                                                                                       6



 Series  TM  TS  TS-C                TM-C                     TM-S                     TM-I
 Reference standard  IEC EN 61558-2-8  IEC EN 61558-2-8  IEC EN 61558-2-6  CEI EN 61558-2-2  CEI EN 61558-2-2                              CEI EN 61558-2-2
                                                              CEI EN 61558-2-6         CEI EN 61558-2-4
 Classification  Fail safe  Non-inherently short-circuit proof  Non-inherently short-circuit proof  Non-short-circuit proof control   Non-short-circuit-proof control    Non-short-circuit-proof control
                                     transformer a            and safety transformer a  and isolating transformer a
 Thermal protection integrated in secondary  n  n
 Rated power  10, 15, 30, 40 VA  8, 16, 24 VA  10, 16, 25, 40, 63, 100 VA  50 to 2500 VA  50 to 2500 VA  50 to 2500 VA
 Operation  Discontinuous  Discontinuous  Continuous  Continuous  Continuous           Continuous
 Primary circuit voltage ratings  230 V a.c.  230 V a.c.  230 V a.c.  230/400 V a.c.  230/400V a.c.  230/400 V a.c.
 Secondary   Double insulation between primary and secondary windings  n  n  n  n      n
 circuit   Full power on all outputs
 characteristics  n                  n                        n                        n
 SELV secondary (no-load output voltage <50 V a.c.)  n  n  n  n
 Dimensions  2 modules [10, 15 VA]  2 modules [8, 16 VA]  2 modules [10 VA]  See overall dimensions 13/60  See overall dimensions 13/60  See overall dimensions 13/60
 3 modules [30, 40 VA]  3 modules [24 VA]  3 modules [16 VA]
           4 modules [25 VA, 40 VA]
           5 modules [63 VA]
           6 modules [100 VA]
  See page 6/58 for the choice of the protections.


                             Bell transformer                    TM, TS
                             Transformers for supplying extra low voltage, suitable for loads that require a discontinuous supply, in particular doorbells
                             and chimes. The primary and secondary circuits are perfectly isolated and separated.
                             Reference standard: IEC EN 61558-2-8


                             Control transformer                 TM-C, TM-S*, TM-I*

                             Transformer for supplying control circuits, for example commands, signaling, interlocks, etc.
                             Reference standard: CEI EN 61558-2-2


                             Safety transformer                  TS-C, TM-S*
                             Isolation transformer for supplying safety extra low voltage circuits (<50 V on no load). Accidental contact with the
                             secondary winding phases can be withstood without any danger.
                             Reference standard: CEI EN 61558-2-6

                             Isolating transformer               TM-I*
                             Transformer in which the primary and secondary windings are electrically separated by a double or reinforced insulation, to
                             protect the circuit supplied by the secondary against hazards due to accidental simultaneous contact with earth and live
                             parts, or grounded parts that may become live in the event of an insulation fault.
                             Reference standard: CEI EN 61558-2-4
          * TM-S and TM-I both comply to two standards.