Page 700 - Din prodcuts 2020
P. 700

6/68             ELECTRICAL INSTALL ATION SOLUTIONS FOR BUILDINGS   2CHC 420 001 C0201




          —
          Command and signaling
          TM-C, TM-S, TM-I control, isolating and safety transformers




                                    TM-C control transformer
                                    Transformer for supplying control circuits, for example commands, signaling, interlocks, etc.
                                    Reference standard: CEI EN 61558-2-2.

      TM-I                          TM-S safety transformer
                                    Isolation transformer for supplying safety extra low voltage circuits (<50 V on no load).
                                    Accidental contact with the secondary winding phases can be withstood without any
  6
                                    danger. Reference standard: CEI EN 61558-2-6
                                    TM-I isolating transformer
                                    Transformer in which the primary and secondary windings are electrically separated by
                                    a double or reinforced insulation, to protect the circuit supplied by the secondary against
                                    hazards due to accidental simultaneous contact with earth and live parts, or grounded parts
                                    that may become live in the event of an insulation fault.
      TM-S
                                    Reference standard: CEI EN 61558-2-4

                                    Since TM-C, TM-S and TM-I transformers are not provided with built-in protection, they must
                                    therefore be protected according with these rules:
                                    •   Primary: line protection must reach or exceed the recommended value in Chapter 6 of
                                     Electrical installation solutions for buildings - Technical details. This device guarantees line
                                     protection and service continuity but doesn‘t protect the transformer.
                                    •  Secondary: transformer protection must be chosen according to tables in the previous
                                     pages. This device protect the transformer.
      TM-C
                                    TM-C single phase control transformers, primary 230-400 V
                                    Rated power  Secondary   Bbn  Order details                  Price Weight Pack
                                              voltage    8012542                               1 piece 1 piece unit

                                    VA        V a.c.     EAN    Type code       Order code           kg     pc.
                                    50        12-24      071136  TM-C 50/12-24  2CSM207113R0801      1.1    1
                                    100       12-24      071037  TM-C 100/12-24  2CSM207103R0801     2      1
                                    160       12-24      368533  TM-C 160/12-24  2CSM236853R0801     3      1
                                    200       12-24      368236  TM-C 200/12-24  2CSM236823R0801     3.2    1
                                    250       12-24      070931  TM-C 250/12-24  2CSM207093R0801     3.6    1
                                    320       12-24      368434  TM-C 320/12-24  2CSM236843R0801     4.4    1
      TM-C
                                    400       12-24      897033  TM-C 400/12-24  2CSM289703R0801     5.5    1
                                    630       12-24      368137  TM-C 630/12-24  2CSM236813R0801     7.8    1
                                    1000      12-24      928737  TM-C 1000/12-24  2CSM292873R0801    13.2   1
                                    1600      12-24      928638  TM-C 1600/12-24  2CSM292863R0801    21.2   1
                                    2000      12-24      928539  TM-C 2000/12-24  2CSM292853R0801    25.5   1
                                    2500      12-24      369431  TM-C 2500/12-24  2CSM236943R0801    26.8   1
                                    50        115-230    072133  TM-C 50/115-230  2CSM207213R0801    1.1    1
                                    100       115-230    369332  TM-C 100/115-230  2CSM236933R0801   2      1
                                    160       115-230    072034  TM-C 160/115-230  2CSM207203R0801   3      1
                                    200       115-230    368830  TM-C 200/115-230  2CSM236883R0801   3.2    1
                                    250       115-230    071532  TM-C 250/115-230  2CSM207153R0801   3.6    1
                                    320       115-230    369233  TM-C 320/115-230  2CSM236923R0801   4.4    1
                                    400       115-230    071938  TM-C 400/115-230  2CSM207193R0801   5.5    1
                                    630       115-230    071839  TM-C 630/115-230  2CSM207183R0801   7.8    1
                                    1000      115-230    369134  TM-C 1000/115-230  2CSM236913R0801  13.2   1
                                    1600      115-230    018131  TM-C 1600/115-230  2CSM201813R0801  21.2   1
                                    2000      115-230    369035  TM-C 2000/115-230  2CSM236903R0801  25.5   1
                                    2500      115-230    071730  TM-C 2500/115-230  2CSM207173R0801  26.8   1
   695   696   697   698   699   700   701   702   703   704   705