Page 703 - Din prodcuts 2020
P. 703

6/71




          —
          Command and signaling
          TM bell transformers




                                    Technical characteristics
                                    Primary rated voltage Un  [V]  230 a.c.
                                    Secondary rated voltage Un  [V]  4, 8, 12, 24
                                    Tolerance on secondary voltage   [%]  +/- 15% (according to standards)
                                    (with load)
                                    Rated frequency         [Hz]   50/60
                                                                                                                       6
                                    Rated power (discontinuous use)  [VA]  10, 15, 30, 40
                                    Power loss (off load)   [W]    <2.5 (TM10, TM15), <3 (TM30, TM40), <1.25 (TM15 ES)
                                    Modules                 [No.]  2 (TM10, TM15), 3 (TM30, TM40)
            TM 15/12
                                                               2
                                    Cable section           [mm -  2.5 - 14
                                                            AWG]
                                    Tightening torque       [Nm]   0.5
                                    Protection degree              IP 20
                                    Standards                      IEC/EN 61558-2-8
                                    Approvals





                                    TM fail safe bell transformers
                                    These transformers, with safety extremely-low voltage secondary (SELV), are suitable
                                    for loads that require a discontinuous supply, and in particular doorbells and chimes.
          TM 40/12                  Fail safe operation and excellent safety are assured thanks to the perfect isolation
                                    and separation between the primary and secondary circuits. In addition, the Energy Saving
                                    TM-ES version allows reducing power losses by 50%.


                                    Maximum      Secondary   Bbn    Order details                Price Weight Pack
                                    rated power a  voltage rating  8012542                     1 piece 1 piece unit
                                    (disccontinuous)
                                    VA           V c.a.      EAN    Type code   Order code           kg     pc.
                                    10           4-8-12      287155  TM10/12    2CSM228715R0802      0.30   6
                                    10           12-24       287254  TM10/24    2CSM228725R0802      0.30   6
                                    15           4-8-12      287353  TM15/12    2CSM228735R0802      0.30   6
                                    15           12-24       287452  TM15/24    2CSM228745R0802      0.30   6
                                    15           4-8-12      285854  TM15/12 ES  2CSM228585R0802     0.30   1
                                    30           4-8-12      287551  TM30/12    2CSM228755R0802      0.45   4
                                    30           12-24       287650  TM30/24    2CSM228765R0802      0.45   4
                                    40           4-8-12      287759  TM40/12    2CSM228775R0802      0.45  4
                                    40           12-24       287858  TM40/24    2CSM228785R0802      0.45  4
                                     
                                     See diagrams below for the RMS power on each secondary output