Page 12 - IDEC timer catalogue
P. 12

RTE Series                                                                           Timers


                                                 Temperature Derating Curves

     Switches & Pilot Lights  Mounting A  Allowable  Current  10A Ambient Temperature                  Allowable  Current   7A Ambient Temperature
                                                                   Mounting B

                                            7A
                                              Mounting A
                                                                                     5A
                                                                                       Mounting B
                                              Derating Curve
                                                                                       Derating Curve
                                                    50ºC 65ºC
                                                                                              50ºC 65ºC
                                                        Instructions

     Display Lights  Installation of Hold-Down Springs  Insert the springs    Switch Settings
         DIN Rail Mount Socket
                     Insert the springs into the outer
                     slots with the projections
                                                       into the slots.
                     facing inside.
                                                                              j               l
                                                                                              k

                                                                                 jOperator Mode Selector
                                            Socket SR2P-05  Hold-down Spring (sold separately)
                                                       SFA-203 (use two springs)  kScale Selector
          Socket SR2P-06  Hold-down Spring (sold separately)                     lTime Range Selector
     Relays & Sockets                                                         1. Turn the selectors securely using a fl at screw-
                       SFA-202 (use two springs)
                                                                               driver 4mm wide (maximum).
                                                                               Note that incorrect setting may cause malfunc-
                                                                               tion. Do not turn the selectors beyond their limits.
                                                                              2. Since changing the setting during timer operation
                                                                               may cause malfunction, turn power off before
                                                                               changing.




     Timers                                         Safety Precautions

        Special expertise is required to use Electronic Timers.  •  Do not use the Electronic Timer for an emergency stop circuit or inter-
                                                                 locking circuit. If the Electronic Timer should fail, a machine malfunction,
        •  All Electronic Timers are manufactured under IDEC’s rigorous quality control   breakdown, or accident may occur.
          system, but users must add a backup or fail safe provision to the control
          system when using the Electronic Timer in applications where heavy damage   Caution
          or personal injury may occur should the Electronic Timer fail.
                                                               Caution notices are used where inattention might cause personal injury or dam-
        •
          Install the Electronic Timer according to instructions described in this catalog.
     Terminal Blocks  •  Make sure that the operating conditions are as described in the specifi ca-  •  The Electronic Timer is designed for installation in equipment. Do not install
                                                               age to equipment.
          tions. If you are uncertain about the specifi cations, contact IDEC in advance.
                                                                 the Electronic Timer outside equipment.
          In these directions, safety precautions are categorized in order of importance
        •
          under Warning and Caution.                           •  Install the Electronic Timer in environments described in the specifi cations. If
                                                                 the Electronic Timer is used in places where it will be subjected to high-tem-
                                                                 perature, high-humidity, condensation, corrosive gases, excessive vibrations,
        Warnings                                                 or excessive shocks, then electrical shocks, fi re hazard, or malfunction could
        Warning notices are used to emphasize that improper operation may cause   result.
        severe personal injury or death.                       •  Use an IEC60127-approved fuse and circuit breaker on the power and output
     Circuit Breakers  •  Turn power off to the Electronic timer before starting installation, removal,   •  Do not disassemble, repair, or modify the Electronic Timer.
                                                                 line outside the Electronic Timer.
          wiring, maintenance, and inspection on the Electronic Timer.
        •
          Failure to turn power off may cause electrical shocks or fi re hazard.
                                                               •
                                                                 When disposing of the Electronic Timer, do so as industrial waste.




      802                                               www.idec.com
   7   8   9   10   11   12   13   14   15   16   17