PROTECTION TRIP UNITS                                                            3/13



















                                                                                                                       03

































                           —                                           •  Communication with all supervision systems

                           All protection trip units in the             available in the Modbus, Profibus and Devi-
                                                                        ceNet™ protocols as well as the modern Mod-
                           SACE Emax 2 family are self-                 bus TCP, Profinet, EtherNet/IP™;
                           powered by current that crosses
                                                                       •  Integration into Smart Grids thanks to the pos-
                           the circuit breaker. They                    sibility of communicating without the assis-
                           guarantee excellent reliability due          tance of any external converter, according to
                                                                        standards (IEC 61850) already in use in the auto-
                           to a system of self-control of               mation systems of high and medium voltage
                           internal connections.                        substations;


                           The setting, testing and downloading of reports  •  Multi-voltage supply module, which enables the
                           can be carried out directly from a Smartphone,   protection trip unit and modules present to be
                           Tablet or PC. In addition, the commissioning   supplied with any auxiliary voltage available in
                           stage can be further accelerated, minimizing the   direct or alternating current;
                           possibility of errors, by directly configuring the
                           protection trip unit with the DOC design soft-  •  Programmable logic management with Ekip
                           ware settings. Cartridge-type modules that are   Signalling modules that provide a high number
                           easily installed on-board enable the units to be in-  of electrical input and output contacts;
                           tegrated into the most complex systems.
                           Additional functions can be created, such as:  •  Logical interlocks between circuit breakers,
                                                                        which can be made with the Ekip Link propri-
                           •  Synchrocheck, to check the synchronization of   etary communication protocol, avoiding com-
                            the two half-busbars before enabling circuit-   plex wiring thanks to the transmission of all sig-
                            breaker closing;                            nals via a bus..