Page 140 - SACE Tmax XT - Catalogue
P. 140

6/6              SACE TMAX XT LOW VOLTAGE MOLDED CASE CIRCUIT-BREAKERS



          —

          Power Controller













                           Benefits                                     Thanks to the integrated communication mod-
                           Thanks to the Tmax XT with embedded the Power   ules, the Power Controller can receive the maxi-
                           Controller, the following benefits are guaranteed:  mum absorbable power directly from the me-
                                                                        dium voltage control system, determining
                           •  Reduction of energy costs with minimum    consumption for the next 15 minutes. According
                            impact                                      to the information received, the Ekip Power
                            The loads are disconnected from the power   Controller manages the switching off of non-
                            supply for short periods, in the minimum num-  priority loads or the switching on of reserve
                            ber necessary and in a fixed order of priority,   generators. The software gives maximum prior-
                            enabling power consumption peaks to be lim-  ity to non-programmable preferred energy
                            ited. This allows the contract drawn up with the   sources, such as wind and solar, and they are
                            energy provider to be renegotiated, reducing   therefore considered uninterruptable. In the
                            the power allocated, with a consequent reduc-  event that the production of internal power to
                            tion in total energy costs.                 the controlled network is reduced, due, for ex-
                           •  Power limited only when necessary         ample, to decreased production of solar power,
                            The Power Controller function manages up to   the Power Controller will disconnect the neces-
                            four different time bands. It is therefore possible   sary loads to respect the set consumption limit.
                            to respect a particular power limit according to   This benefit is used, for example, in installations
                            whether it is during the day (peak) or night (off   with a system of cogeneration. Indeed, the
                            peak). In this way, consumption during the day   Power Controller controls the total consumption
                            when rates are at their highest can be limited.  drawn from the electrical network, disconnect-
                           •  Easy of use                                                      ing non-priority loads when generation is re-
                            The Power Controller function allows the instal-  duced and reconnecting them when generator
                            lation to be managed efficiently with a simple   power is sufficient not to exceed limits.
                            architecture. Thanks to a patented design, it is   There are multiple advantages of the system
                            sufficient to measure the total power of the in-  including: reduction in energy costs, maximum
                            stallation without having to measure the power   use of local generation and greater overall en-
                            consumed by each load. Installation costs and   ergy efficiency.
                            times are thereby reduced to a minimum.
                            The Power Controller function does not require
                            the writing, implementation or testing of com-
                            plicated programmes for PLC or computer be-
                            cause the logic has already been implemented
                            in the protection unit and is ready to use. It is
                            sufficient to set the installation parameters
                            from a smartphone or directly from the switch-
                            ing device display.