7/2              SACE TMAX XT LOW VOLTAGE MOLDED CASE CIRCUIT-BREAKERS



          —

          Execution and installation













                           Fixed, plug-in and withdrawable version
                           SACE Tmax XT circuit-breakers are available in the following versions:

                           •  FIXED
                            Fixed circuit-breakers consist of a current-interrupting part connected to the trip unit, to be installed
                            on the back plate of the cubicle or on a DIN-rail;

          —
          Fixed circuit-breaker
                           •  PLUG-IN
                            Plug-in circuit-breakers consist of a fixed part that must be installed on the back plate of the cubicle,
                            and of a moving part, obtained from the fixed circuit-breaker plus the relative kit that converts it
                            from the fixed version into the moving part of the plug-in version;

          —
          Plug-in circuit-breaker
                           •  WITHDRAWABLE
                            Withdrawable circuit-breakers consist of a fixed part that must be installed on the back plate of the
                            cubicle equipped with side runners to allow the moving part to be easily racked -in and -out. Such a
                            solution is obtained from the fixed circuit-breaker plus the relative kit that converts it from the fixed
          —
          Withdrawable      version to a withdrawable moving part. To obtain the withdrawable version, a front accessory to be
          circuit-breaker   applied to the front of the circuit-breaker must be ordered so as to maintain the IP40 degree of pro-
                            tection over the entire disconnection run of the circuit-breaker (except for the XT7). This mandatory
                            accessory is a standard supply for circuit-breakers fitted with accessories in the factory.


                           If the plug-in circuit-breaker is fitted with electrical accessories, the appropriate connectors for dis-
                           connection of the relative auxiliary circuits must also be ordered. For the withdrawable version there
                           are dedicated accessories, fitted with connectors, which allow automatic disconnection in the case of
                           racking-out.
                           Starting from the fixed version, the SACE Tmax XT circuit-breakers can be easily converted into plug-in
                           and withdrawable versions by using the relative conversion kits.
                           The moving parts can always be obtained for the required version, fully pre-engineered from the factory,
                           by ordering the fixed circuit-breaker and the conversion kit at the same time.

                                      Version
                                      Fixed                    Plug-in                 Withdrawable
                           XT1                                                       -
                           XT2                                                       
                           XT3                                                       -
                           XT4                                                       
                           XT5                                                       
                           XT6                                -                         (1)
                           XT7                                -                       
                           XT7 M                              -                       
                           (1) In max = 800A, not suitable for XT6 1000A