7/16             SACE TMAX XT LOW VOLTAGE MOLDED CASE CIRCUIT-BREAKERS



          —

          Signaling














                           Signaling                                       XT1  XT2  XT3  XT4  XT5  XT6  XT7  XT7 M
                           Auxiliary contact  1Q + 1SY 24V DC                                    -   -
                                              3Q + 1SY 24V DC              -                      -   -
                           Q: open/close signaling
                           contact            1Q + 1SY on the left 24V DC  -    -   -    -       -    -   -
                                              1S51 24V DC                  -       -                  
                           SY: trip signaling contact
                                              1S52 24V DC                  -    -   -    -              -
                           S51: trip unit signaling   1Q + 1SY 250V AC/DC                        -   -
                           contact
                                              2Q + 1SY 250V AC/DC                                -   -
                           S52: YO or YU trip   2Q + 2SY + 1S51 250V AC/DC  -      -       -    -    -   -
                           signaling contact  3Q + 1SY 250V AC/DC          -                      -   -
                                              3Q + 2SY 250V AC/DC          -                      -   -
                                              3Q on the left 250V AC/DC                   -   -    -   -
                                              1Q + 1SY on the left 250V AC/DC  -  -  -   -       -    -   -
                                              1S51 250V AC/DC              -       -                  
                                              1S52 250V AC/DC              -    -   -    -              -
                                              1Q + 1SY 400V AC             -       -           -    -   -
                                              2Q 400V AC                   -       -           -    -   -
                                              2Q 400V AC + 2Q 24V DC       -    -   -    -    -   -       
                                              4Q 24V DC                    -    -   -    -    -   -       
                                              4Q 400V AC                   -    -   -    -    -           
                                              15Q 24V DC                   -    -   -    -    -   -    -   
                                              15Q 400V AC                  -    -   -    -    -   -    -   
                                              AUP - Racked-in                                       
                           Position contacts  AUP - Racked-out             -       -                  
                                              AUP - Test                   -    -   -    -              
                                              AUE in closing                                        -
                           Early auxiliary contacts
                                              AUE in opening                              -   -    -   -
                           Ready to close contact  RTC - Ready to close signaling contact  -  -  -  -  -  -  -  
                                              S33 M/2 - Contact signaling loaded
                           Loaded springs                                  -    -    -   -    -   -    -   
                                              springs
                                              TU Reset - Mechanical signaling of the
                           TU Reset                                        -    -    -   -    -   -    -   
                                              tripping of protection trip unit