Page 164 - SACE Tmax XT - Catalogue
P. 164

7/18             SACE TMAX XT LOW VOLTAGE MOLDED CASE CIRCUIT-BREAKERS



          —

          Signaling













                           250V AC/DC and 24V AC/DC auxiliary contacts are installed without the need for any screws. They are
                           extremely easy to fit. Simply apply a slight pressure in the appropriate place. The following versions of
                           auxiliary contacts are available:
                                                           2
                           •  cabled (AWG20 cable section -0.5mm ):
                               - for fixed/plug-in circuit-breakers with 1m long cables;
                               - for withdrawable circuit-breakers with fixed part and moving part connector;
          —                •  not cabled:
          Cabled auxiliary contact    - for fixed/plug-in circuit-breakers with cables from 0.5 up to 1.5 mm  cross-section.
                                                                                     2
                           Auxiliary contacts are supplied for each circuit-breaker in the SACE XT family in various different com-
                           binations, as shown in the table. The following items can be ordered to make the installation even more
                           flexible:
                           •  an uncabled auxiliary contact can generate different signals (Q, SY or S52) according to the position
                            that the circuit-breaker is installed at;
                           •  an uncabled S51 auxiliary contact, which can be used for XT2, XT4, XT5 and XT6 circuit-breakers;
                           •  a cabled auxiliary contact, with unnumbered cables. It can generate different signals (Q, SY or S52)
          —
          Uncabled auxiliary    according to the position where the circuit-breaker is installed.
          contact
                           Combinations of cabled auxiliary   XT1      XT2          XT3            XT4
                           contacts with numbered cables  3/4p         3/4p         3/4p           3/4p
                           1Q 1SY 24V DC                 F-P           F-P-W        F-P            F-P-W
                           3Q 1SY 24V DC                 –             F-P-W        F-P            F-P-W
                           1S51 24V DC                   –             F-P-W        –              F-P-W
          —                1Q 1SY 250V AC/DC             F-P           F-P-W        F-P            F-P-W
          Cabled auxiliary contact
          for withdrawable   2Q 2SY 1S51 250V AC/DC      –             F-P-W        –              F-P-W
          circuit-breaker  3Q 2SY 250V AC/DC             –             F-P-W        –              F-P-W
                           3Q 1SY 250V AC/DC             –             F-P-W        F-P            F-P-W
                           1S51 250V AC/DC               –             F-P-W        –              F-P-W
                           2Q 1SY 250V AC/DC             F-P           F-P          F-P            F-P
                           3Q on the left 250V AC/DC     F-P           F-P          F-P            F-P
                           F = Fixed, P = Plug-in, W = Withdrawable

                           Combinations of cabled auxiliary   XT5                                  XT6
                           contacts with numbered cables  Thermal-magnetic and   Ekip Touch and
                                                         Ekip Dip trip unit   Hi-Touch trip unit
                           1Q + 1SY on the left 24V DC   F-P                  -                    -
                           1Q + 1SY 24V DC               F-P-W                F-P-W                F-W
                           3Q + 1SY 24V DC               F-P-W                F-P-W                F-W
                           1S51 24V DC                   F-P-W                F-P-W                F-W
                           1S52 24V DC                   F-P-W                F-P-W                F-W
                           1Q + 1SY on the left 250V AC/DC  F-P               -                    -
                           1Q + 1SY 250V AC/DC           F-P-W                F-P-W                F-W
                           2Q + 1SY 250V AC/DC           F-P-W                F-P-W                F-W
                           3Q + 1SY 250V DC              F-P-W                F-P-W                F-W
                           1S51 250V AC/DC               F-P-W                F-P-W                F-W
                           1S52 250V AC/DC               F-P-W                F-P-W                F-W
                           F = Fixed, P = Plug-in, W = Withdrawable