          Compatibility of accessories













                           Fixed and plug-in versions
                           Check whether the different devices are compatible/incompatible with each other when ordering ac-
                           cessories. The following table provides a simple check of the compatibility between mechanical and
                           electrical accessories. To understand the abbreviations used to identify the accessories more easily, refer
                           to the "Glossary" at the end of the section.
              3p   1p      How to read compatibility tables - an example
                           Fixed/plug-in circuit-breaker compatibility XT1-XT3
                                         SOR         UVR        3Q          SOR         UVR         .....
                                         3p          3p         3p          4p          4p
                           SOR 3p                                           ✔           ✔
                           UVR 3p  1          2           3          4      ✔  5        ✔  6
                           3Q sx 3p                                         ✔           ✔
                           SOR 4p        ✔           ✔          ✔                       ✔
          —
          Three-pole cir-  UVR 4p        ✔           ✔          ✔           ✔ [...]
          cuit-breaker
                           [...]
                 3p  1p
              4p
                                                                (1)
                           The UVR positioned in the slot of the 3rd pole  is:
                                                                   rd
                                                                        (2)
                           •  incompatible with the SOR positioned on the 3  pole ;
                                                                        (3)
                           •  incompatible with the UVR positioned on the 3  pole ;
                                                                   rd
                                                                             (4)
                                                                        rd
                           •  incompatible with the 3Q contacts on the left of the 3  pole ;
                                                                         th
                           •  compatible with the SOR positioned in the slot of the 4  pole ;
                                                                              (5)
                           •  compatible with the UVR positioned in the slot of the 4  pole .
                                                                         th
                                                                              (6)
                           •  [...]
          —                                                                                                            07
          Four-pole circuit-breaker
                           Tmax XT1-XT3
                                           RHD  RHE  RHS  FLD  MOD  PLL on CB  KLC on CB  RHL  MOL on motor  SOR/UVR 3p  3Q left 3p  RC SA 3p  SOR/UVR 4p  3Q left 4p  1Q+1SY  2Q+1SY  3Q+1SY  AUE
                           RHD                                       ✔       ✔   ✔   ✔   ✔   ✔   ✔   ✔   ✔   ✔
                           RHE                                       ✔       ✔   ✔   ✔   ✔   ✔   ✔   ✔   ✔   ✔
                           RHS                                               ✔   ✔   ✔   ✔   ✔   ✔   ✔   ✔
                           FLD                                       ✔       ✔   ✔   ✔   ✔   ✔   ✔   ✔   ✔
                           MOD                                           ✔   ✔   ✔   ✔   ✔   ✔   ✔   ✔  (1)  ✔  (2)
                           PLL on CB                                         ✔   ✔   ✔   ✔   ✔   ✔   ✔   ✔
                           KLC on CB                                                     ✔   ✔   ✔   ✔   ✔
                           RHL            ✔   ✔       ✔                      ✔   ✔   ✔   ✔   ✔   ✔   ✔   ✔   ✔
                           MOL on motor                   ✔                  ✔   ✔       ✔   ✔   ✔   ✔   ✔
                           SOR/UVR 3p     ✔   ✔   ✔   ✔   ✔   ✔      ✔   ✔               ✔   ✔   ✔   ✔   ✔   ✔
                           3Q left 3p     ✔   ✔   ✔   ✔   ✔   ✔      ✔   ✔               ✔   ✔   ✔   ✔   ✔   ✔
                           RC SA 3p       ✔   ✔   ✔   ✔   ✔   ✔       ✔                  ✔   ✔   ✔   ✔   ✔   ✔
                           SOR/UVR 4p     ✔   ✔   ✔   ✔   ✔   ✔   ✔   ✔  ✔   ✔   ✔   ✔           ✔   ✔   ✔   ✔
                           3Q left 4p     ✔   ✔   ✔   ✔   ✔   ✔   ✔   ✔  ✔   ✔   ✔   ✔           ✔   ✔   ✔   ✔
                           1Q+1SY         ✔   ✔   ✔   ✔   ✔   ✔   ✔   ✔  ✔   ✔   ✔   ✔   ✔   ✔               ✔
                           2Q+1SY         ✔   ✔   ✔   ✔   ✔   ✔   ✔   ✔  ✔   ✔   ✔   ✔   ✔   ✔               ✔
                           3Q+1SY         ✔   ✔   ✔   ✔  ✔  (2)  ✔  ✔  ✔  ✔  ✔   ✔   ✔   ✔   ✔               ✔
                           AUE            ✔   ✔                      ✔       ✔   ✔   ✔   ✔   ✔   ✔   ✔   ✔
                           ✔  Compatible;  (1) Not valid for XT1;  (2) Not valid for XT3