THE RANGES                                                                       2/13










                                                                                                                       02










 Size  XT4                                XT5                                                XT6
 Rated uninterrupted current  [A]  160 / 250  400 / 630                                      800
 Poles  [No.]  3, 4                       3, 4                                               3, 4
 Rated service voltage, Ue  (DC)  [V]  750  750                                              750
 Rated insulation voltage, Ui  (DC)  [V]  1000  1,000                                       1,000
 Rated impulse withstand voltage, Uimp  [kV]  8  8                                            8
 Versions  Fixed, Withdrawable, Plug-in  Fixed, Withdrawable, Plug-in                  Fixed, Withdrawable
 Breaking capacities according to IEC 60947-2  N  S  H  L  V  X  N  S  H  L  V  X  N          S          H
 Rated ultimate short-circuit breaking capacity, Icu
 Icu @ 250V (DC) 2 poles in series  [kA]  36  50  70  85  100  100  25  35  50  70  85  100  35  50      70
 Icu @ 500V (DC) 2 poles in series  [kA]  36  50  70  85  100  100  25  35  50  70  85  100  20  35      50
 Icu @ 500V (DC) 3 poles in series  [kA]  36  50  70  85  100  100  -  -  -  -  -  -  -       -          -
 Icu @ 750V (DC) 3p in series  [kA]  -  -  -  -  50  70  -  -  -  -  85  100      18         24          36
 Rated service short-circuit breaking capacity, Ics
 Ics @ 250V (DC) 2 poles in series  [kA]  100%  100%  100%  100%  100%  100%  100%  100%  100%  100%  100%  100%  100%  50% (35kA)  50%
 Ics @ 500V (DC) 2 poles in series  [kA]  100%  100%  100%  100%  100%  100%  100%  100%  100%  100%  100%  100%  100%  50%  50%
 Ics @ 500V (DC) 3 poles in series  [kA]  100%  100%  100%  100%  100%  100%  -  -  -  -  -  -  -  -     -
 Ics @ 750V (DC) 3 poles in series  [kA]  -  -  -  -  100%  100%  -  -  -  -  100%  100%  100%  75%     50%
 Utilization Category (IEC 60947-2)  A     A                                                  A
 Reference Standard  IEC 60947-2       IEC 60947-2                                        IEC 60947-2
 Insulation behaviour                                                                       
 Mounted on DIN rail  DIN EN 50022         -                                                  -
 Mechanical life  [No. Operations]  25,000  20,000                                          20,000
 [No. Hourly operations]  240             120                                                120
 Dimensions
 Fixed  3 poles  [mm]  105 x 82.5 x 160  140 x 103 x 205                                210 x 103.5 x 268
 (Width x Depth x Height)    4 poles  [mm]  140 x 82.5 x 160  186 x 103 x 205           280 x 103.5 x 268
 Trip units
 TMD/TMA                                                                                    
 TMD/TMF
 MF/MA  
 Trip units with low magnetic (TMG)
 TMG                                       
 Interchangeable trip units                                                                 
 Weight
 Fixed                                                                                    3/4 poles  [kg]  2.5 / 3.5  3.25 / 4.15  9.5 / 12
 Plug in (EF terminals)                                                           3/4 poles  [kg]  4.19 / 5.52  5.15 / 6.65  -
 Withdrawable (EF terminals)                                              3/4 poles  [kg]  5 / 6.76  5.4 / 6.9  12.1 / 15.1
   26   27   28   29   30   31   32   33   34   35   36