Page 335 - SACE Tmax XT - Technical Catalogue
P. 335

WIRING DIAGR AMS                                                              3/5



















                                                                                                                       03








                           86/1-2    = Contacts controlled by Auto/Manual   W2    = Serial interface with internal bus (local
                                     selector switch of direct action motor      bus)
                                     operator                          W9...14   = Connector RJ45 for interface unit and
                           S75E/1-2  = Contacts for signaling circuit-breaker      for communication modules
                                     in withdrawn position (only applicable    W9R...12R  = Connector RJ45 for redundant
                                     to withdrawable circuit-breaker ver         communication modules
                                     sions)                            X3-X4-X8 = Protection relay connectors
                           S75l/1-2-5  = Contacts for signaling circuit-breaker    X41    = Connector of current circuit for extenal
                                     in racked-in position (only applicable      neutral
                                     to withdrawable or plug-in circuit-    XB..    = Three-way connector for auxiliary
                                     breaker versions)                           circuits of plug-in circuit-breaker
                           S87/1    = Contact for electrical signaling of   XC..    = Six-way connector for auxiliary circuits
                                     residual current relay prealarm             of plug-in circuit-breaker
                           S87/2    = Contact for electrical signaling of   XC2-3    = Six-way connector for auxiliary circuits
                                     residual current relay alarm                of plug-in circuit-breaker for voltage
                           S87/3    = Contact for electrical signaling of        up to 400V
                                     circuit-breaker open due to residual   XCT1-2   = Terminal box of Ekip DIN Rail Cartridge
                                     current relay trip                          Basic or Ekip DIN Rail Cartridge
                           SC      = Pushbutton or contact for closing the    XD..    = Nine-way connector for auxiliary
                                     circuit-breaker                             circuits of plug-in circuit-breaker
                           SC3     = Motor start pushbutton            XE..    = Fifteen-way connector for auxiliary
                           SD      = Residual current relay supply               circuits of plug-in circuit-breaker
                                     disconnector                      XF..    = Ekip Com type interface unit connector
                           SO      = Pushbutton or contact for opening   XG    = Protection relay connector
                                     circuit-breaker                   XH1     = Protection relay connector
                           SO3     = Motor stop pushbutton             XK7     = Connector of contact S75l/5
                           SR      = Electrical reset pushbutton or contact  XM    = MOE-E actuator unit connector
                           SY/1...3  = Contacts for signaling circuit-breaker    XV    = Terminal box of circuit-breaker
                                     open due to tripped overcurrent             applications
                                     protection relay, thermomagnetic   YC     = Closing coil of stored energy motor
                                     release and coils Y0, YO1, Y02, YU          operator
                                     (tripped position)                YO      = Opening coil
                           Tl      = Toroidal current transformer      YO1     = Coil for opening due to overcurrent
                           Tl/L1-L2-L3 = L1-L2-L3 phase current transformer  YO2    = Opening coil of residual current relay
                           Tl/N    = Current transformer on neutral    YU      = Undervoltage coil
                           TU2     = Insulation voltage transformer (out
                                     side circuit-breaker)
                           Uaux    = Auxiliary supply voltage
                           V1      = Circuit-breaker applications
                           V2      = Motor operator applications
                           V4      = Indicative switchgear and connec-
                                     tions for operation and signaling, out
                                     side circuit-breaker
                           V5      = Ekip DIN Rail Cartridge Basic or Ekip
                                     DIN Rail Cartridge applications
   330   331   332   333   334   335   336   337   338   339   340