Page 173 - Surge-Protection-E_0.pdf
P. 173

Pluggable SPDs – DIN Rail Mounted


           BLITZDUCTOR XTU – Protection Modules with LifeCheck
           BXTU ML4 BD 0-180                                                                                920 349   BXTU ML4 BD 0-180
           Space-saving combined lightning current and surge arrester module with actiVsense technology and RFID LifeCheck for protecting two pairs
           (same or different operating voltage) of balanced interfaces with galvanic isolation.            920 349        4013364126404  04 02 01 03   25 g
                                                                                                             217,30 €
           Type BXTU ...                           ML4 BD 0-180
           Part No.                                920 349
           SPD class                               M
           Max. continuous operating voltage (d.c.)  (UC)  180 V
           Permissible superimposed signal voltage  (Usignal)  ≤ +/- 5 V
                                                                                                 1              1‘
           Cut-off frequency line-line (Usignal, balanced 100 ohms)  (fG)  50 MHz                      i  U>U N
           Nominal current at 80 °C (equal to max. short-circuit current)  (IL)  100 mA          2              2‘    Pluggable SPDs –   DIN Rail Mounted
                                                                                                       i
           D1 Total lightning impulse current (10/350 µs)  (Iimp)  10 kA                                         protected
                                                                                                 3              3‘
           C2 Total nominal discharge current (8/20 µs)  (In)  20 kA                                   i  U>U N
           Series resistance per line              ≤ 10 ohms; typically 7.5 ohms                 4              4‘
                                                                                                       i
           Approvals                               CSA, UL, EAC, SIL

           BXTU ML2 BD S 0-180                                                                              920 249   BXTU ML2 BD S 0-180
           Space-saving combined lightning current and surge arrester module with actiVsense technology and RFID LifeCheck for protecting one pair
           of balanced interfaces with galvanic isolation. Direct or indirect shield earthing.              920 249        4013364127845  04 02 01 03   23 g
                                                                                                             150,00 €
           Type BXTU ...                           ML2 BD S 0-180
           Part No.                                920 249
           SPD class                               M
           Max. continuous operating voltage (d.c.)  (UC)  180 V
           Permissible superimposed signal voltage  (Usignal)  ≤ +/- 5 V                         1               1‘
                                                                                                       i  U>U N
           Cut-off frequency line-line (Usignal, balanced 100 ohms)  (fG)  50 MHz
           Nominal current at 80 °C (equal to max. short-circuit current)  (IL)  100 mA          2     i         2‘
           D1 Total lightning impulse current (10/350 µs)  (Iimp)  9 kA                                          protected
           C2 Total nominal discharge current (8/20 µs)  (In)  20 kA                             3               3‘
           Series resistance per line              ≤ 10 ohms; typically 7.5 ohms                 4               4‘
           Approvals                               CSA, UL, EAC, SIL

















































           Valid as of August 1, 2020                         You will find detailed product information on our website   169
   168   169   170   171   172   173   174   175   176   177   178