Pluggable SPDs – DIN Rail Mounted

            926 371
            BSP M4 BD HF
            5            BSP M4 BD HF 5 / 24
            926 375
            BSP M4 BD HF
            24
                         Space-saving surge arrester module for protecting two pairs of high-frequency bus systems or video transmission systems with galvanic
        926 371   4013364127289  04 02 01 04      22 g
              144,70 €   isolation.
        926 375   4013364129382  04 02 01 04      22 g
              144,70 €
                          Type BSP ...                      M4 BD HF 5               M4 BD HF 24
                          Part No.                          926 371 (                926 375 (
                          SPD class                         Q                        Q
        1               1‘
                          Max. continuous operating voltage (d.c.)  (UC)  6.0 V      33 V
                          Nominal current at 45 °C  (IL)    1.0 A                    1.0 A
        2               2‘
                        protected  3‘  D1 Lightning impulse current (10/350 µs) per line  (Iimp)  1 kA  1 kA
                                                                                     20 kA
                          C2 Total nominal discharge current (8/20 µs)  (In)
                                                            20 kA
   Pluggable SPDs –   DIN Rail Mounted  4  4‘  Cut-off frequency line-line  (fG)  100.0 MHz  100.0 MHz
        3
                                                            UL, CSA, SIL, EAC
                          Approvals
                                                                                     UL, CSA, EAC
        926 240   BSP M2 BD 5
        926 242   BSP M2 BD 12
        926 244   BSP M2 BD 24  BSP M2 BD 5 – BD 180
        926 245   BSP M2 BD 48
        926 246   BSP M2 BD 60
        926 247   BSP M2 BD 180
                         Space-saving surge arrester module for protecting one pair of balanced interfaces with galvanic isolation.
        926 240   4013364127074  04 02 01 04      21 g
              86,70 €
        926 242   4013364127081  04 02 01 04      21 g
              86,70 €
        926 244   4013364127098  04 02 01 04      21 g
              86,70 €
        926 245   4013364127104  04 02 01 04      21 g
              86,70 €
        926 246   4013364127111  04 02 01 04      21 g   General technical data:
              86,70 €
        926 247   4013364127128  04 02 01 04      21 g
              80,60 €
                          D1 Lightning impulse current (10/350 µs) per line  (Iimp)  1 kA
                          C2 Total nominal discharge current (8/20 µs)  (In)  20 kA
                          Approvals                         UL, CSA, SIL, EAC
                          Type BSP ...                      M2 BD 5     M2 BD 12     M2 BD 24
                          Part No.                          926 240 (   926 242 (    926 244 (
        1               1‘
                          SPD class                         Q           Q            Q
        2               2‘  Max. continuous operating voltage (d.c.)  (UC)  6.0 V  15 V  33 V
                        protected  Nominal current at 45 °C  (IL)  1.0 A  1.0 A      1.0 A
                          Cut-off frequency line-line  (fG)  1.0 MHz    2.8 MHz      7.8 MHz
        3               3‘
                          Type BSP ...                      M2 BD 48    M2 BD 60     M2 BD 180
        4               4‘
                          Part No.                          926 245 (   926 246 (    926 247 (
                          SPD class                         Q           Q            R
                          Max. continuous operating voltage (d.c.)  (UC)  54 V  70 V  180 V
                          Nominal current at 45 °C  (IL)    1.0 A       1.0 A        0.75 A
                          Cut-off frequency line-line  (fG)  8.7 MHz    11 MHz       25.0 MHz
            926 270
            BSP M2 BE HF
            5            BSP M2 BE HF 5
                         Space-saving surge arrester module for protecting two single lines sharing a common reference potential and high-frequency transmissions
        926 270   4013364127135  04 02 01 04      21 g
              97,70 €    without galvanic isolation.
                          Type BSP ...                      M2 BE HF 5
                          Part No.                          926 270 (
                          SPD class                         Q
                          Max. continuous operating voltage (d.c.)  (UC)  6.0 V
        1               1‘
                          Nominal current at 45 °C  (IL)    1.0 A
        2               2‘
                          D1 Lightning impulse current (10/350 µs) per line  (Iimp)  1 kA
                        protected  C2 Total nominal discharge current (8/20 µs)  (In)  20 kA
                          Cut-off frequency line-PG  (fG)   100 MHz
        3               3‘
                          Approvals                         UL, CSA, SIL, EAC
        4               4‘
            926 271
            BSP M2 BD HF
            5            BSP M2 BD HF 5 / 24
            926 275
            BSP M2 BD HF
            24
                         Space-saving surge arrester module for protecting one pair of high-frequency bus systems or video transmission systems with galvanic
        926 271   4013364127142  04 02 01 04      21 g
              97,70 €    isolation.
        926 275   4013364129351  04 02 01 04      21 g
              97,70 €
                          Type BSP ...                      M2 BD HF 5               M2 BD HF 24
                          Part No.                          926 271 (                926 275 (
                          SPD class                         Q                        Q
                          Max. continuous operating voltage (d.c.)  (UC)  6.0 V      33 V
        1               1‘
                          Nominal current at 45 °C  (IL)    1.0 A                    1.0 A
        2               2‘
                        protected  D1 Lightning impulse current (10/350 µs) per line  (Iimp)  1 kA  1 kA
                                                            20 kA
                          C2 Total nominal discharge current (8/20 µs)  (In)
                                                                                     20 kA
                          Cut-off frequency line-line  (fG)  100 MHz                 100 MHz
        3               3‘
                          Approvals                         UL, CSA, SIL, EAC        UL, CSA, EAC
        4               4‘