SPDs for Building Systems
DPRO 230 NT 909 310 DPRO 230 NT
Combined surge protection for the power and data side of a digital network termination (NT). Also suited for telephones and fax machines.
With visual operating state and fault indication and integrated child safety mechanism. 909 310 4013364117747 04 02 07 01 212 g
86,50 €
Type DPRO 230 ... NT
Part No. 909 310
Protection of the data side
SPD class Q
Max. continuous operating voltage (d.c.) (UC) 180 V
Lightning impulse current (10/350 µs) per line D1 (Iimp) 1 kA
C2 Nominal discharge current (8/20 µs) per line (In) 2.5 kA
Cut-off frequency (fG) 50 MHz
Connection (input / output) RJ12 socket / RJ12 socket
Protection of the power side
SPD according to EN 61643-11 / IEC 61643-11 type 3 / class III
Max. continuous operating voltage (a.c.) (UC) 255 V (50 / 60 Hz)
Total discharge current (8/20 µs) [L+N-PE] (Itotal) 5 kA
Voltage protection level [L-N] (Up) ≤ 1.25 kV
Max. mains-side overcurrent protection B 16 A
DPRO 230 ISDN 909 320 DPRO 230 ISDN
Combined surge protection for the power and ISDN S0 side of ISDN systems and devices. Shielded port makes it suitable for protecting
Ethernet 10 BT. With visual operating state and fault indication and integrated child safety mechanism. 909 320 4013364136885 04 02 07 01 215 g
112,30 €
Type DPRO 230 ... ISDN
Part No. 909 320 (
Protection of the data side
SPD class Q
Max. continuous operating voltage (d.c.) (UC) 48 V
Lightning impulse current (10/350 µs) per line D1 (Iimp) 1 kA
C2 Total nominal discharge current (8/20 µs) (In) 10 kA
Cut-off frequency (fG) 50 MHz
Connection (input / output) shielded RJ45 socket / shielded RJ45 socket
Protection of the power side
SPD according to EN 61643-11 / IEC 61643-11 type 3 / class III
Max. continuous operating voltage (a.c.) (UC) 255 V (50 / 60 Hz)
Total discharge current (8/20 µs) [L+N-PE] (Itotal) 5 kA
Voltage protection level [L-N] (Up) ≤ 1.25 kV
Max. mains-side overcurrent protection B 16 A
DPRO 230 LAN100 909 321 DPRO 230 LAN100
Combined surge protection for the power side and data input for protecting LAN components.
Protection of all pairs for Ethernet pin assignment. 909 321 4013364126152 04 02 07 01 222 g Building Systems
133,90 €
It meets the requirements for channel class D in accordance with EN 50173 and is thus suitable for 1000 Base-T (Gigabit Ethernet). SPDs for
With visual operating state and fault indication and integrated child safety mechanism.
Type DPRO 230 ... LAN100
Part No. 909 321
Protection of the data side
SPD class Q
Max. continuous operating voltage (d.c.) (UC) 58 V
Lightning impulse current (10/350 µs) per line D1 (Iimp) 1 kA
C2 Total nominal discharge current (8/20 µs) (In) 10 kA
Cut-off frequency (fG) 120 MHz
Connection (input / output) shielded RJ45 socket / shielded RJ45 socket
Protection of the power side
SPD according to EN 61643-11 / IEC 61643-11 type 3 / class III
Max. continuous operating voltage (a.c.) (UC) 255 V (50 / 60 Hz)
Total discharge current (8/20 µs) [L+N-PE] (Itotal) 5 kA
Voltage protection level [L-N] (Up) ≤ 1.25 kV
Max. mains-side overcurrent protection B 16 A
Valid as of August 1, 2020 You will find detailed product information on our website 217