SPDs for Coaxial Connection
UGKF
• Plug-in surge protective adapter for easy retrofitting
• Plugs directly into coaxial terminal equipment
• Integrated indirect shield earthing avoids ground loops
Surge arrester designed as a cable adapter for protecting coaxial systems such as
video and camera systems from potential damage.
UGKF BNC shielded surge arresters are plugged into coaxial terminal We recommend using DGA BNC VC... arresters for easy installation on a
equipment or connections. Common applications include the protection DIN rail. These space-saving surge arresters have BNC sockets and protect
of outdoor video surveillance systems or video control centres. In order to video and camera systems. Two versions are available: DGA BNC VCD with
avoid ground loops, the cable shield is earthed indirectly via a gas dis- direct connection of the cable shield to the earth potential or DGA BNC
charge tube. The arrester entries are sockets and the protected outputs VCID with indirect connection of the cable shield. The arresters are earthed
plugs. via the DIN rail.
Devices for video systems with a higher supply voltage or sockets on both
ends are available on request.
UGKF BNC can be directly plugged UL listing for country-specific use. DGA BNC VC ... can be easily adapted DGA BNC VC... can be easily mounted
into the interfaces of terminal equip- due to BNC connection. on DIN rails or walls.
ment.
UGKF BNC
929 010 UGKF BNC
Two-stage surge arrester with indirect shield earthing for protecting video cameras and Arcnet with BNC connection to avoid ground loops.
929 010 4013364039940 04 02 08 01 68 g
145,10 €
Type UGKF BNC
Part No. 929 010
SPD class T
Max. continuous operating voltage (d.c.) (UC) 8 V
Nominal current (IL) 0.1 A
C2 Nominal discharge current (8/20 µs) line-shield (In) 2.5 kA
Insertion loss at 300 MHz (50 ohms)
≤ 3 dB
Ableiter für koaxialen Anschluss Return loss at 40 MHz (50 ohms) ≥ 20 dB
Insertion loss at 265 MHz (75 ohms)
≤ 3 dB
Return loss at 40 MHz (75 ohms)
≥ 20 dB
Approvals CSA, UL, EAC
DGA BNC VC
909 710 DGA BNC VCD
909 711 DGA BNC VCID
The space-saving surge arrester with BNC socket can be mounted on DIN rails for protecting video and camera systems.
909 710 4013364118942 04 02 08 01 114 g
146,00 € Available with direct (VCD) or indirect shield connection (VCID) depending on the type to avoid ground loops.
909 711 4013364118980 04 02 08 01 116 g
150,00 €
Type DGA ... BNC VCD BNC VCID
Part No. 909 710 909 711
SPD class T T
Max. continuous operating voltage (d.c.) (UC) 6.4 V 6.4 V
Nominal current (IL) 0.1 A 0.1 A
D1 Lightning impulse current (10/350 µs) (Iimp) 1 kA 1 kA
C2 Nominal discharge current (8/20 µs) line-shield (In) 5 kA 5 kA
Frequency range 0-300 MHz 0-300 MHz
Connection (input / output) BNC socket / BNC socket BNC socket / BNC socket
Approvals CSA, UL CSA, UL