Page 80 - Surge-Protection-E_0.pdf
P. 80

Surge Arresters – Type 2

        900 780   SPD+POP 2 255 C25
        900 781   SPD+POP 2 255 C32
        900 782   SPD+POP 2 255 C40  Two-pole SPD+POP+MCB
                          Type SPD+POP ...                  2 255 C25   2 255 C32    2 255 C40
        900 780   4013364156203  04 01 02 20   368 g   1
        pc(s)  141,70 €
        900 781   4013364156210  04 01 02 20   390 g   1
        pc(s)  143,70 €
        900 782   4013364156227  04 01 02 20   389 g   1
        pc(s)  145,30 €   Part No.                          900 780     900 781      900 782
                          SPD+POP+MCB
                          Number of poles                   1P + N      1P + N       1P + N
                          Nominal a.c. voltage  (UN)        230 V       230 V        230 V
                          SPD
                          Nominal discharge current (8/20 μs) [L-N] (In)  5 kA  5 kA  5 kA
                          MCB
                          Tripping characteristic           C           C            C
                          Nominal alternating current (In)  25 A        32 A         40 A

        900 785   SPD+POP 4 255 C25
        900 786   SPD+POP 4 255 C32
        900 787   SPD+POP 4 255 C40  Four-pole SPD+POP+MCB
        900 788   SPD+POP 4 255 C63
                          Type SPD+POP ...                  4 255 C25   4 255 C32    4 255 C40    4 255 C63
        900 785   4013364156234  04 01 02 20   693 g
              394,70 €
        900 786   4013364156241  04 01 02 20   726 g
              399,85 €
        900 787   4013364156258  04 01 02 20   732 g
              421,25 €
        900 788   4013364156265  04 01 02 20   736 g   Part No.  900 785  900 786    900 787      900 788
              479,15 €
                          SPD+POP+MCB
                          Number of poles                   3P + N      3P + N       3P + N       3P + N
                          Nominal a.c. voltage  (UN)        230 / 400 V  230 / 400 V  230 / 400 V  230 / 400 V
                          SPD
                          Nominal discharge current (8/20) [L-N]  (In)  5 kA  5 kA   5 kA         5 kA
                          MCB
                          Tripping characteristic           C           C            C            C
                          Nominal alternating current  (In)  25 A       32 A         40 A         63 A
        900 760   POP 2 255 C25
        900 761   POP 2 255 C32  Two-pole POP+MCB
        900 762   POP 2 255 C40
                          Type POP ...                      2 255 C25   2 255 C32    2 255 C40
        900 760   4013364156135  04 01 02 20   274 g
              99,05 €
        900 761   4013364156142  04 01 02 20   294 g
              102,25 €
        900 762   4013364156159  04 01 02 20   294 g
              109,60 €    Part No.                          900 760     900 761      900 762
                          POP+MCB
                          Number of poles                   1P + N      1P + N       1P + N
                          Nominal a.c. voltage  (UN)        230 V       230 V        230 V
                          MCB
                          Tripping characteristic           C           C            C
                          Nominal alternating current  (In)  25 A       32 A         40 A
        900 765   POP 4 255 C25
        900 766   POP 4 255 C32
        900 767   POP 4 255 C40  Four-pole POP+MCB
        900 768   POP 4 255 C63
                          Type POP ...                      4 255 C25   4 255 C32    4 255 C40    4 255 C63
        900 765   4013364156166  04 01 02 20   512 g
              263,10 €
        900 766   4013364156173  04 01 02 20   545 g
              291,35 €
        900 767   4013364156180  04 01 02 20   551 g
          900 768          297,00 € 4013364156197  04 01 02 20   556 g   Part No.  900 765  900 766  900 767  900 768
    Surge Arresters – Type 2  Number of poles               3P + N      3P + N       3P + N       3P + N
         329,80 €
                          POP+MCB
                                                            230 / 400 V
                                                                                                  230 / 400 V
                                                                        230 / 400 V
                                                                                     230 / 400 V
                          Nominal a.c. voltage  (UN)
                          MCB
                          Tripping characteristic
                                                                                                  63 A
                                                                                     40 A
                          Nominal alternating current  (In)  C          C            C            C
                                                            25 A
                                                                        32 A













        76               You will find detailed product information on our website             Valid as of August 1, 2020
   75   76   77   78   79   80   81   82   83   84   85