Page 81 - Surge-Protection-E_0.pdf
P. 81

Surge Arresters – Type 2


           DEHNcord
           • Single-pole, two-pole or three-pole surge protective device
            with monitoring system and disconnector
           • Visual fault indication
           • Types with disconnection of the load circuit in the event
            of a fault and protection of the control phase
           • Compact design also for outdoor use
           • Can be fitted in junction boxes, flush-mounted systems,
            cable ducts and flush-type boxes






                                                                For protecting electronic devices (e.g. LED lights, smart poles, wall boxes or techni-
                                                                cal building equipment) from surges. For flexible installation in electrical installa-
                                                                tion systems such as flush-type boxes. Due to its compact design, the arrester can
                                                                always be installed in the right place in the relevant installation area. For instal-
                                                                lation in conformity with the lightning protection zone concept at the boundaries
                                                                from 0B – 1 and higher.

           DEHNcord L 1P …:     Compact single-pole version; e.g. for use in luminaires of protection class 1
           DEHNcord L 2P …:     Compact two-pole version; e.g. for use in luminaires of protection class 2 or in flush-type boxes,
                                flush-mounted systems and cable ducts
           DEHNcord L 3P … SO LTG:   Compact three-pole version; for use in the junction boxes of LED light poles with disconnection
                                of the load circuit in the event of a fault and for protecting the control phase
           SK EK480 G2S-2d LM DCOR:  EK480 fuse box with integrated DEHNcord L 3P 275 SO LTG surge protective device (Part No. 900 445)
           DEHNcord R 3P …:     Compact three-pole version; for use with electric sun shading systems
           DEHNcord 3P ...:     Compact three-phase version; for use in confined spaces, e.g. in a wall box


           The DEHNcord series can be used flexibly as a type 2 surge arrester, thus   LED lights are optimally protected against
           offering a variety of different application options. The surge arresters are   surges by the DEHNcord series. The LTG ver-
           ideally suited for protecting electrical and electronic consumers wherever   sion is ideally suited for integration in fuse
           the performance of a standard type 3 surge protective device for terminal   boxes. Thanks to its adapted design, the de-
           equipment reaches its limits. The new three-phase DEHNcord is ideally   vice fits perfectly into the upper area of the
           suited for applications in wall boxes, smart poles and in building technol-  EK480 junction box from Langmatz.
           ogy. Due to its extremely compact design, the device can be used in con-  If no junction box is installed in the LED light,
           fined spaces. In addition, universal installation is possible without addi-  the EK480 fuse box with integrated
           tional installation material. The push-in double terminals ensure fast   DEHNcord surge protective device can be
           wiring.                                                                 used as a complete solution. The innovative
           Another important field of application is the protection of outdoor LED   plug-in technology allows the wires to be
           lights. The DEHNcord L … SO LTG version is particularly suitable of this   connected  to  the  luminaire  without  tools,
           purpose and can be integrated in the junction box of an LED light pole.   and the system can be installed more quickly.
           This version additionally allows a control phase to be protected and the   Should it become necessary, the surge pro-
           load circuit to be interrupted if the DEHNcord arrester is faulty. This makes   tective device can be easily replaced at any
           it considerably easier to detect faults, thus facilitating testing and main-  time.                        Surge Arresters – Type 2
           tenance of the system. Despite the powerful protective circuit, the com-
           pact enclosure also houses a disconnector and a visual operating state /
           fault indicator. DEHNcord is a type 2 surge arrester and can therefore be
           installed according to the lightning protection zones concept at the tran-  The multipole DEHNcord R 3P adapter is a type 2 surge arrester.  It protects
           sition from 0B – 1 and higher. This ensures installation of surge protective   sun shading systems and Venetian blinds and is installed in the connecting
           devices in line with the standard wherever space is restricted.   cables of the drive. In addition, this version can also be used to protect
           The IP type can both be integrated in junction boxes and directly in the   buildings against surges induced on the building facade. DEHNcord R 3P
                                                                meets the requirements of the lightning protection zone concept as well
           pole (cables can be entered into any junction box thanks to IP 65 degree   as the installation standard for buildings IEC 60364-4-44/-5-53.
           of protection).



















           Valid as of August 1, 2020                         You will find detailed product information on our website   77