Surge Arresters – Type 2

                         DEHNcord L 2P 275 SO LT
        900 435   DCOR L 2P 275 SO LT
                         Two-pole surge arrester for TNC systems; compact design. With disconnection of the load circuit in the event of a fault and protection of the
        900 435   4013364292963  04 01 02 05   54 g
              58,00 €    control phase.
                          Type                              DCOR L 2P 275 SO LT
           60  30.3  19.4  Part No.                         900 435
                          SPD according to EN 61643-11 / IEC 61643-11  type 2 / class II
                  62.8  67  Max. continuous operating voltage (a.c.) [L-PEN]  (UC)  275 V (50 / 60 Hz)
                          Nominal discharge current (8/20 µs)  (In)  5 kA
                          Max. discharge current (8/20 µs)  (Imax)  10 kA
                          Voltage protection level [L-PEN]  (UP)  ≤ 1.5 kV
                          Max. mains-side overcurrent protection  B 16 A
                          Approvals                         KEMA



         L‘  L    L  ST  PEN



                     50  DEHNcord L 3P 275 SO IP
        900 447   DCOR L 3P 275 SO IP
                   30    Three-pole surge arrester for all installation systems; compact design. IP 65 degree of protection.
                      Ø5.5
        900 447   4013364282216  04 01 02 05   130 g
              70,00 €    With disconnection of the load circuit in the event of a fault and protection of the control phase.
                  48    42.8  Type                          DCOR L 3P 275 SO IP
                          Part No.                          900 447
                   80
                          SPD according to EN 61643-11 / IEC 61643-11  type 2 / class II
                  290   280  Max. continuous operating voltage (a.c.) [L-N]  (UC)  275 V (50 / 60 Hz)
                          Nominal discharge current (8/20 µs)  (In)  5 kA
                          Max. discharge current (8/20 µs)  (Imax)  10 kA
                          Voltage protection level [L-N]  (UP)  ≤ 1.5 kV
                          Voltage protection level [N-PE]  (UP)  ≤ 1.5 kV
                          Max. mains-side overcurrent protection  B 16 A



         L‘  L  L  ST  N  PE


        900 448   DCOR L 2P 275 SO IP  50  DEHNcord L 2P 275 SO IP
                   30    Two-pole arrester for all installation systems; compact design. IP 65 degree of protection.
                      Ø5.5
        900 448   4013364293007  04 01 02 05   113 g
              59,00 €    With disconnection of the load circuit in the event of a fault.
                  48    42.8  Type                          DCOR L 2P 275 SO IP
                          Part No.                          900 448
                   80
                          SPD according to EN 61643-11 / IEC 61643-11  type 2 / class II
                  290   280  Max. continuous operating voltage (a.c.) [L-N]  (UC)  275 V (50 / 60 Hz)
                          Nominal discharge current (8/20 µs)  (In)  5 kA
    Surge Arresters – Type 2  Voltage protection level [L-N]  (UP)  ≤ 1.5 kV
                                                            10 kA
                          Max. discharge current (8/20 µs)  (Imax)
                                                            ≤ 1.5 kV
                          Voltage protection level [N-PE]  (UP)
                          Max. mains-side overcurrent protection
                                                            B 16 A



          L‘  L  N   PE


                         DEHNcord R 3P
        900 449   DCOR R 3P 275
                         Surge arrester for electric Venetian blinds; compact design.
        900 449   4013364320031  04 01 02 05   129 g
              151,20 €
                          Type                              DCOR R 3P 275
                          Part No.                          900 449
                38
               136        SPD according to EN 61643-11 / IEC 61643-11  type 2 / class II
               150        Max. continuous operating voltage (a.c.) [L-N]  (UC)  275 V (50 / 60 Hz)
                33        Nominal discharge current (8/20 µs)  (In)  2.5 kA
                          Max. discharge current (8/20 µs)  (Imax)  5 kA
        PE             9
                          Voltage protection level [L-N]  (UP)  ≤ 1.5 kV
        9
                          Connector                         Hirschmann STAK 3 / STAS 3
        L   auf        L   auf
        L ab           L ab
        N              N

        80               You will find detailed product information on our website             Valid as of August 1, 2020
   79   80   81   82   83   84   85   86   87   88   89