Page 280 - V16 Catalogue Final
P. 280

STANDALONE RELAYS




                                               MAINSPRO (VOLTAGE BASED)
          Features:                            Description                                           Part No.
          - AS4777 Compliant.                  Mains Decoupling Relay                                MainsPro
          - IEC60255 Certified.
          - G59 Certified.
          - Under and Over Voltage.            Protective Functionality                              ANSI
          - Under and Over frequency.          Overvoltage                                           59
          - Vector Shift.                      Under voltage                                         27
          - Rate Of Change Of Frequency (ROCOF).  Over Frequency                                     81H
                                               Under Frequency                                       81L
          Approvals:                           Voltage Unbalance                                     47
          - Ausgrid, SAPN, SP Ausnet, CitiPower/Powercor.
                                               Vector Shift                                          78
                                               ROCOF                                                 81R


                                               Description          Measuring Range  Control Voltage  Part No.
                                               Grid Monitoring Relay  L-L up to 520V AC,   8-40, 110-370V DC  MAINSPRO
                                                                    L-N up to 290V AC  85-265V AC




                       MainsPro



                                               INTELIPROPV (CURRENT & VOLTAGE BASED)
          Features:                            Description                                           Part No.
          - AS4777 Compliant.                  Utility Protection Relay                              InteliProPV
          - IEC60255 Certified.
          - G59 Certified.                     Protective Functionality                              ANSI
          - Under and Over Voltage.
          - Under and Over frequency.          Under/overvoltage and asymmetry (two stage setting)   27, 59, 47
          - Vector Shift.                      Overfrequency, Underfrequency (two stage setting)     81H, 81L
          - Rate Of Change Of Frequency (ROCOF).  Instantaneous over current                         50
          - Export Limitation.                 Time over current                                     51
          - Analogue Output for Inverter Modulation.  Current asymmetry                              46
          - Neutral Voltage Displacement.      Earth fault current                                   50N + 51N
          - GSM, Ethernet or RS485 interface.
                                               Ground surge current                                  50GS + 51GS
          Approvals:                           Directional/Reverse power with time delay             32
          - Ausgrid, SP Ausnet, CitiPower/Pwercor, Energex,     Neutral voltage displacement         59N
            Ergon Energy, Western Power, ACTEWAGL,   Vector shift                                    78
            PAWA.                              Rate of change of frequency + rocof filter            81R
                                               Auto fault reset
          Optional Protections:
          - Synch Check - ANSI25.              Maximum parallel time
          - Time over Current with voltage control - ANSI51V.  Analog and binary inputs related protections
          - Directional Overcurrent - ANSI67.  Battery voltage protection
          - Pole Slip Protection - ANSI78PS.   Breaker failure
          - AC Reclosing relay - ANSI79.

                                               Description          Measuring Range  Control Voltage  Part No.
                                               Grid Monitoring Relay  L-L up to 480V AC,   8-36V DC  INTELIPROPV
                                                                    L-N up to 340V AC








                       InteliProPV





    272   V16-PV-R04                                    www.ipd.com.au                             Phone: 1300 556 601