Page 281 - V16 Catalogue Final
P. 281

STANDALONE RELAY - ABB
        The CM-UFD.M33 is a multifunctional grid feeding monitoring relay. It provides different monitoring functions to detect Over and Under voltage (10 minutes average
        value, voltage increase and decrease protection) as well as any changes in grid frequency (Frequency increase and decrease protection).
        The device is connected between the distributed generation and the public grid in order to disconnect the distributed generation in case of problems (e.g unstable grid)
        faults or maintenance on the grid. Additionally, monitoring of ROCOF (Rate of change of frequency) and vector shift can be configured.
                                             CM-UFD.M33 - VOLTAGE BASED                                          PHOTOVOLTAIC
        Features:                             Description                                          Part No.
        - Monitoring of voltage and frequency in single and   Multifunctional Grid protection relay  CM-UFD.M33
           three phase mains (2-wire, 3-wire or 4-wire AC
           systems).
        - Pre-settings in accordance with G59/3 and G83/2.  Protective Functionality               ANSI
        - Integrated management of redundancy function.  Overvoltage                               59
        - Multiline, backlit LCD display.     Under voltage                                        27
        - True RMS measuring principle.       Over Frequency                                       81H
        - Over and Under voltage, 10 minutes average as well   Under Frequency                     81L
           as Over and Under frequency monitoring.
        - Two level threshold settings for Over/Under voltage   Vector Shift                       78
           and Over/Under frequency.          ROCOF                                                81R
        - ROCOF (Rate of Change of frequency) monitoring
           and vector shift configurable.
        - Interrupted natural detection.
        - All threshold values and tripping delays adjustable.  CM-UFD.M33M - VOLTAGE BASED - MODBUS RTU INTERFACE
        - Error memory for up to 99 entries (incl. cause of error,
           measured value, relative timestamp).  Description                                       Part No.
        - Test function.                      Multifunctional Grid protection relay                CM-UFD.M33M
        - Password setting protection.
        - 3 control inputs, e.g for feedback signal, Remote trip.
        - 3 c/o (SPDT) contacts.              Protective Functionality                             ANSI
        - Various certifications and approvals.  Overvoltage                                       59
                                              Under voltage                                        27
                                              Over Frequency                                       81H
                                              Under Frequency                                      81L
                                              Vector Shift                                         78
                                              ROCOF                                                81R

                                              Description         Measuring Range  Control Voltage  Part No.
                                              Grid Monitoring Relay  L-L  0-540V AC,   24-240V AC/DC  CM-UFD.M33
                                                                  L-N  0-312V AC

                     CM-UFD.M33














                     Renewable energy system             Decoupling unit                         Public grid


                                        Modbus
                                         RTU
                     Integra on into ABB Ability TM
                     Electrical Distribu on Control System



                                        Modbus
                                         RTU


                     Remote PLC for processing &     Grid feeding monitoring relay
                     visualiza on of measurement values  CM-UFD.M*M with Modbus RTU

        Phone: 1300 556 601                            www.ipd.com.au                                  V16-PV-R04  273
   276   277   278   279   280   281   282   283   284   285   286