Page 28 - VSD_Brochure_31102023
P. 28

WATER DRIVES




        Optimising the flow of water and wastewater in your
        pumping solutions


         The ACQ580 water and wastewater drive is built to help users, designers, OEMs, system
        integrators and EPC professionals secure pumping of water and wastewater in
        municipal utilities, pumping stations, industrial wastewater facilities, desalination plants
        and irrigation environments. It offers long-term, technically-compatible drive solutions                                     Sleep boost                                                Auto-change
                                                                                                                                     Save energy while extending the life                       Increase the mean time between repairs
        supported by full service and support.
                                                                                                                                     time of the pumps and motors by                            and save in service costs by balancing
                                                                                                                                     decreasing start/stop cycles during                        the long-term operation time of all
                                                                                                                                     all hours of the day.                                      pumps in a parallel pumping system.






                                                                                                                                                                                                            Level control
                                                                                                                                                                                                            Ensure optimal efficiency when
                                                                                                                                                                                                            filling or emptying a tank.
           Soft pipe filling
           Increase the lifetime of the piping
           and pump system by avoiding
           pressure peaks.








                                                                                                                                                                                                            Sensorless flow calculation
                                                                                                                                                                                                            Reduce costs by eliminating the
           Quick ramps                                                                                                                                                                                      need for external components
           Extend the lifecycle of submersible                                                                                                                                                              or backup the flow meters to
           pumps by reducing wear of the                                                                                                                                                                    avoid interruptions in the
           mechanical parts using ramp sets to                                                                                                                                                              process.
           accelerate and decelerate the pumps.





                                                                                                                                                                                                            Flow and pressure protection
                                                                                                                                                                                                            Protect the pumping system
                                                                                                                                                                                                            from a low and/or high
                                                                                                                                                                                                            pressure and flow, as well as
                                                                                                                                                                                                            prevent the pump from
           Pump priority                                                                                                                                                                                    running dry.
           Achieve energy savings with optimal
           pump alternation by running the higher
           capacity pumps when the consumption
           rate is higher.




                                                                                                                                                                                                Pump cleaning
                                                                                                                                                                                                Achieve savings by preventing unplanned
                                                                                                                                                                                                downtime. This is made possible as a result of
                                                                                                                                                                                                accumulating obstructions being removed
           Anti-cavitation                                     Multi-pump control                                                                                                               from the impeller of the pump.
           Extend the pump lifetime and secure                 Ensure stable and uninterrupted production with
           the process by detecting cavitation and             multi-pump controls by optimising the speed and
           ensuring optimal pump speed.                        number of running pumps.




        28  |  Variable Speed Drives                                                                                                                                                                                 Variable Speed Drives  |  29