Page 39 - VSD_Brochure_31102023
P. 39

HVAC DRIVES

                Soft start and stop                                   Fireman’s override
                User defined ramps for softer fan/                    In case of fire emergency, drives run
                pump/compressor starts and stops                      fans ignoring faults and warnings, to
 Software characteristics for the ACH580 HVAC   eliminate mechanical and electrical   ensure safe evacuation and mitigate
                stresses on the system.                               the spread of smoke.
 drives family


 The ACH580 drives come with a range of advanced features that not only provide a
                Flying start                                          Active braking
 thorough heating, ventilation and air conditioning control, but also make drive integration,
                The feature allows to catch                           In case of fire emergency, drives run
 commissioning, and operation easier than ever before.
                free-wheeling fans and smoothly                       fans ignoring faults and warnings, to
                accelerate or decelerate them to a                    ensure safe evacuation and mitigate
                required speed, without wasting time                  the spread of smoke.
                on braking.


                Air filter monitoring                                 Motor heating
                The drive alarms on a clogged filter, to              The feature prevents condensation
                maintain air quality and avoid energy                 and saves the motor from failure due
                losses.                                               to corrosion, which is typical for rooftop
                                                                      mounted air handlers.




                Leakage monitoring                                    Bearing monitoring
                In closed loop HVAC systems, drives                   Bearings are one of the weakest points
                can alarm on the leakage in the                       in HVAC applications. Drives can alarm
                system, preventing flooding and                       on the bearing upcoming failure, so it
                property damage.                                      could be replaced timely, without HVAC
                                                                      process interruption.



                Resonance monitoring                                   Intelligent pump control
                Mechanical aspect of resonance                         The feature maintains stable pumping
                damages the application itself                         process for up to 8 pumps operating
                and connected piping/ductwork,                         in parallel. It is possible to optimise
                while acoustic aspect makes the                        the speed and number of pumps for
                environment noisy. ABB drives skip                     creating required flow and pressure,
                resonance frequencies for better                       even if one or more pumps fail.
                comfort and longer equipment lifetime.





                System overpressure protection                        Pump dry run protection
                The interlock protects water pipes/air                The interlock stops operation when the
                ducts by stopping pump/fan operation                  pressure on the pump suction side is
                when the measured pressure exceeds                    below a threshold, to prevent pump
                a threshold, e.g. due to closed valves/               damage from running dry.
                dampers.



                Sleep/boost                                           Frost protection
                The feature stops the pump at low                     Cold temperatures outside might
                demand, instead of running it slowly                  lead to heating coil freezing. To avoid
                below its efficient operating range.                  damage, drives can alarm on a too
                Allows to save energy and extend                      low air temperature and shut down the
                the pump and motor lifetime by                        system.
                decreasing start/stop cycles during the
                day.