HVAC DRIVES


 1
 Premier HVAC control
    5



 ABB HVAC drives are ideal for
 all your HVAC applications,
 such as air-handling units,   3
 chillers, and cooling towers.   2
 They are suitable for use in a
 wide range of facilities from
 residential and commercial
 buildings to hospitals, data
 centres, airports and tunnels.
             4





 4



                                                                              6




















 1  Cooling tower  2  Chiller  4  Chilled and hot water             6  Air handling unit
              circulator pumps
 Cools down the condenser   Chills water or other   •  Mechanical resonance
 water.   liquid to cool down and   speeds can be avoided.  Circulate water (or other liquid) between   Supplies, mixes, cleans, humidifies/
 •  The drive controls the speed of   dehumidify the indoor air.   •  Maximum speed is not   heating coil and boiler or cooling coil and   dehumidifies, heats/cools air.
 multiple fans simultaneously to   •  The drive controls the speed   limited by nominal supply   chiller.  •   Drives can be used to:
 achieve high energy savings,   of the compressor for better   frequency.  •  The cooling and heating loads vary a lot     – Control the speed of supply and return
 while optimising the installation   energy efficiency.  •  Less stress to supply   over time. Speed controlled circulator   fans
 cost.  •  By-pass valves can be   network as high inrush   pumps make sure that an adequate     – Eliminate mechanical stress
 avoided  currents can be avoided   amount of heating or cooling is distributed     – Avoid fan resonance
 •  Less mechanical stress as   with VSD controlled start   in the building.    – Control the speed and efficiency of the
 there are less starts and   optimising the installation   •  Soft start and stop of the pump reduces   rotary heat exchangers
 stops, and they are soft.  cost.  hydraulic stress on pipelines and valves.    – Control the dampers
                                                                            – Monitor AHU condition including filter
                                                                          clogging, fan belts and heating coil
                                                                          freeze
 3  Condenser water pump  5  Boiler
                                                                      •  ABB HVAC drives’ override mode secures
 Circulates water between the cooling tower and the chiller.   Heats up the water for building heating/  drive operation in case of fire.
 •  Energy savings can be achieved with variable frequency drives that adjust pump   domestic hot water supply.
 speed to the cooling load.  •  The drive controls the burner fan to adjust
                the amount of combustion air to the
                heating load.