HVAC DRIVES  HVAC DRIVES




 General software features                                              Take advantage of flexible,
                                                                        cabinet-free installation

                                                                        Save space and reduce
                                                                        overall costs
                                                                        Maintain process continuity
                                                                        in harsh conditions
 Startup assistant allows first-time users to quickly customise the drive according to their needs.
 This is complemented by a built-in help function to make parameter-by-parameter setting easy.
                                                                        Minimise downtime and
                                                                        optimise HVAC operation
 Motor control is implemented in scalar and vector control modes for induction,
 permanent magnet and synchronous reluctance motors. Motor protection
                                             All-in-one drive for wall mounting
 features like thermal and overload protection are also established.
 The energy optimiser feature optimises the motor flux so that  ACH580 WALL MOUNT DRIVES - 0.75kW TO 250kW - IP55
 total energy consumption and motor noise level are reduced  Features:  Standard Duty  Light Duty
          •  Compact, robust and reliable design
 when the drive operates below the nominal load.                        Frame
          •  Adaptive programming for        Output   Output   Output   Output   Model             Part No.
 The total efficiency can be improved by 1…20%  Current   Power   Current   Power   Size
           customisation
                                             (A)    (kW)   (A)    (kW)
 depending on load torque and speed.  •  EMC C2 filter allows safe installation in
           first environment                 Rated Supply Voltage AC (V): 380 - 480, three phases
 Energy counter monitors used and saved energy  •  Integrated safe torque off (STO)   2.6  0.75  2.5  0.75  R1  ACH580-01-02A7-4+B056  3AXD50000038998
           function
 by the motor and displays it in kWh, currency or  3.3  1.1  3.1  1.1   R1     ACH580-01-03A4-4+B056  3AXD50000038999
          •  Compliance with the highest safety
 CO  emissions, to know how much exactly     4      1.5    3.8    1.5   R1     ACH580-01-04A1-4+B056  3AXD50000039000
 2         performance level (SIL 3/PL e)
 was saved by the drive.  •  Complete HVAC functionality  5.6  2.2  5.3  2.2  R1  ACH580-01-05A7-4+B056  3AXD50000039001
          •  Dry clean air-cooling method    7.2    3      6.8    3     R1     ACH580-01-07A3-4+B056  3AXD50000039002
 Drive safety and protection features include  •  Scalar control for effortless process   9.4  4  8.9  4  R1  ACH580-01-09A5-4+B056  3AXD50000039003
           control                           12.6   5.5    12     5.5   R1     ACH580-01-12A7-4+B056  3AXD50000039004
 overcurrent, DC over- and undervoltage, drive
          •  Vector control for accurate speed and   17  7.5  16.2  7.5  R2    ACH580-01-018A-4+B056  3AXD50000039010
 overheating and short circuit protection, motor
           torque control
                                             25     11     23.8   11    R2     ACH580-01-026A-4+B056  3AXD50000039011
 phase loss and supply phase loss detection,  •  Extensive I/O connections for flexible
                                             32     15     30.4   15    R3     ACH580-01-033A-4+B056  3AXD50000039012
 local control loss detection and many more.  configuration
                                             38     18.5   36.1   18.5  R3     ACH580-01-039A-4+B056  3AXD50000039013
                                             45     22     42.8   22    R3     ACH580-01-046A-4+B056  3AXD50000039014
 People and machine safety is ensured with drive-
                                             62     30     58     30    R4     ACH580-01-062A-4+B056  3AUA0000083598
 based safe-torque-off feature, also allowing to
                                             73     37     68.4   37    R4     ACH580-01-073A-4+B056  3AUA0000083599
 conduct maintenance on the mechanical parts of
                                             88     45     82.7   45    R5     ACH580-01-088A-4+B056  3AUA0000083602
 equipment without shutting it down.
                                             106    55     100    55    R5     ACH580-01-106A-4+B056  3AUA0000083603
                                             145    75     138    75    R6     ACH580-01-145A-4+B056  3AUA0000083604
 Diagnostic assistant helps in locating the cause of  169  90  161  90  R7     ACH580-01-169A-4+B056  3AUA0000083605
 any disturbance to the drive, and even suggests  206  110  196   110   R7     ACH580-01-206A-4+B056  3AUA0000083606
 possible remedies. This reduces process downtime  246  132  234  132   R8     ACH580-01-246A-4+B056  3AUA0000083607
 by making repairs or adjustments effortless.  293  160    278    160   R8     ACH580-01-293A-4+B056  3AUA0000083608
                                             363    200    345    200   R9     ACH580-01-363A-4+B056  3AUA0000083609
 A built-in process PID/loop controller      430    250    400    200   R9     ACH580-01-430A-4+B056  3AUA0000083610

 makes the drive a self-governing unit that requires  -  +B056 = Drives with IP55 protection
                    3AUA0000083604           -  +J400 = ACH-AP-H assistant control panel (as standard)
 no external logic input from the control room but requires
 only an external process measurement.
                                             DIMENSIONS AND WEIGHTS
  Backup and restore feature makes automatic and manual
 backups of the drive settings to the assistant panel.  Frame   H        W            D             Weight
                                             Size           (mm)         (mm)         (mm)          (kg)
 A backup can be restored to another drive.
                                             R1             403          128          233           4.8
                                             R2             503          128          239           6.8
 Adaptive programming provides extra flexibility by offering  H
                                             R3             490          206          237           13
 easy alternative for simple programming needs. Download Drive
                                             R4             636          203          265           20
 Composer entry for free to start writing your application.
                                             R5             732          203          320           29
                                             R6             727          252          380           43
                    D
                                             R7             880          284          381           56
                           W
                                             R8             965          300          452           77
                                             R9             955          380          477           103
                                             -  H = Height of the drive with gland box
                                             -  W  = Width
                                             -  D   = Standard depth
 42  |  Variable Speed Drives                                                                 Variable Speed Drives  |  43
   38   39   40   41   42   43   44   45   46   47   48