Page 147 - MCCB-XT2-XT4
P. 147

ABB | SACE Tmax XT

            Configurations via menu Local bus activation, which is essential for starting the communication between module and Ekip Touch,
                                    is available in the Settings menu (page 29).
                                    The following communication parameters can be configured if the module has been correctly detected by
                                    Ekip Touch in the Settings-Modules menu:
                                     Parameter                 Description                                Default
                                                               Defines whether the module has the dynamic (Off) or
                                     Static IP address ON      static (On) IP address.                    OFF
                                                               Se = On all the associated parameters are enabled
                                     Static address IP address  Enables the static IP to be selected      0.0.0.0
                                     Static Network Mask       Enables the subnet mask to be selected     0.0.0.0
                                                               When there are several subnets, enables the IP
                                     Static Gateway address    address of the node to which the module is connected  0.0.0.0
                                                               to be selected
                                                               Allows the SNTP protocol for distribution of the clock
                                     Enable SNTP client                                                   OFF
                                                               and synchronization signal to be enabled.
                                                               Allows the network server that supplies the SNTP to
                                     SNTP Server Addr.                                                    0.0.0.0
                                                               be set.
                                                               Defines the write mode of the configuration file in the
                                                               module via the TFTP port; two options are available:
                                                                • Always ON: the TFTP port is always open and write
                                     Configuration Session     is always enabled                          Always
                                                                                                          ON
                                                                • Activation requested: the TFTP is opened by a
                                                               specific command, which enables write for a limited
                                                               time (or for a finite number of data packages)
                                                               Write enable command on TFTP port in Activation
                                     Start Configuration                                                  ---
                                                               mode requested



                Information in menu The following information will be available in the About-Modules menu if Ekip Touch has detected the
                                    module correctly:
                                     Information        Description
                                     SN and version     Identifier and SW version of the module
                                                        Address of the module, assigned to the module by a DHCP server at the
                                                        time of connection to the network in the case of configuration with a
                                     IP address         dynamic IP, or can be set via the menu in the event of a static IP
                                                            NOTE: without a DHCP server, the module automatically adopts a
                                                            random IP address within the 169.254.xxx.xxx range
                                                        Subnet mask; identifies the method for recognizing the subnet to which
                                     Network Mask       the modules belong and enables modules to be searched for within a
                                                        defined set of recipients.
                                                        IP address of the node to which the module is connected, in the presence
                                     Gateway address
                                                        of several subnets
                                                        Address assigned by ABB, with OUI (Organizationally Unique Identifier)
                                     MAC address        equal to ac:d3:64, which uniquely identifies the manufacturer of an
                                                        Ethernet device
                                     Cfg file           Name of the configuration file uploaded to the modules
                                     Cfg file error     Code of the error concerning the configuration file (0 = no error)























       145 | © 2022 ABB |  1SDH002031A1002 - ECN000212994                External electronic accessories | 10 - Ekip Com IEC 61850
   142   143   144   145   146   147   148   149   150   151   152