Page 15 - MCCB-XT5
P. 15

ABB | SACE Tmax XT

       3 - Accessories and software



                   Internal modules Ekip Touch is always supplied with the following modules:
                                     Name                  Function                                     Page
                                     Rating Plug  (1)      Defines rated current In                     127
                                     Measurement  (2)      Measurement from installation voltage        128

                                    (1)  Assembled by default at the time equipment is ordered; can be replaced afterwards with a model
                                    of a different size
                                    (2)  The functions of the module are available if the Measuring measures package is present


                External accessories The functions of Ekip Touch can be expanded by further accessories and external modules, which differ
                                    as to function and assembly method.
                                    The main external modules are:
                                     Name                  Function                                     Page
                                     Ekip Supply           Power supply                                 131
                                     Ekip Com              Communication (with various protocols)       132
                                                           Communication via intranet with ABB proprietary
                                     Ekip Link                                                          155
                                                           protocol
                                     Ekip Signalling 2K    Signalling with inputs/outputs               163
                                     Ekip Signalling 3T    Signalling with analog inputs                173
                                                           Voltage measurement and synchronism between two
                                     Ekip Synchrocheck                                                  167
                                                           supply sources
                                     Ekip CI               Command module for motor applications        176

                                    These moduoles must always be connected to the Trip unit using the Elip Cartridge DIN Rail accessory
                                    and only if there are no internal accessories present (page 130).
                                    Other external modules and accessories, available with direct connections to the internal terminal box or
                                    rear connectors, are:

                                     Name                  Function                                     Page
                                     Ekip Signalling 10K   Signalling with inputs/outputs               205
                                     Ekip Multimeter       Panel front display                          206
                                     External neutral      Neutral protection with 3P CB                206


                                    (1)  Presence of auxiliary supply required and, for terminal box models, of Ekip Supply

                                    In addition, the supervision, configuration and reporting functions are provided by further modules for
                                    temporary communication and supply:
                                     Name                  Function                                     Page
                                     Ekip TT               Supply and tests
                                     Ekip T&P              Supply, communication, programming and tests  207
                                     Ekip Programming      Supply, communication and programming




                Internal accessories The SACE XT5 circuit-breaker has a compartment for connection certain internal modules to the Trip unit:
                                     Name           Function                               Page
                                     Ekip Com       Communication (various protocols)      179
                                     Ekip Signalling 1K  Signalling with inputs/outputs    200
                                     Ekip Maintanance  Signalling with inputs/outputs      202
                                     Micro I/O      CB status signaling                    204

                                    These modules connect to the Trip unit directly to the internal terminal box and only if there are no external
                                    accessories (with the exclusion of Ekip Signalling 10K, Ekip Multimeter and External neutral).






       13 | © 2022 ABB |  1SDH002039A1002 - ECN000212994                       Trip unit Overview | 3 - Accessories and software