HVI power Conductor
5 Sealing End Range on a Building
If HVI power Conductors are installed on a building, the calculated separation distance "s" in the sealing end range from metal parts on the
building must be maintained. The sealing end range extends from the EB connection element to the earth-termination connection element.
If the HVI power Conductor is directly connected with an earth entry rod / earth-termination system, an EB element is not necessary. The
sealing end range thus also remains unconsidered.
Air solid
material
r ≥ sair r ≥ sair x 2
1, 2
sealing end range 1800 mm r ≥ sair
HVI power Conductor
3
Accessories for theSealing End Range on a Building
EB Connection element for HVI power / HVI power long Conductor
EB connection element for discharging the electric field of the HVI power Conductor (pre-assembled / on a reel) in the sealing end range.
Special slotted design to electrically contact the semi-conductive sheath. 1
Part No. 410 239
PU 1 pc(s)
KS connector
With screw and nut M10.
Part No. 301 019 2
PU 100 pc(s)
Disconnecting clamp
Disconnecting clamp with spring washer for connecting the HVI power Conductor with the earth entry rod.
Lightning current carrying capability 200 kA (10/350 µs). 3
Part No. 459 200
PU 1 pc(s)